logo
Send Message
products
PRODUCTS DETAILS
Home > Products >
ISO 80369-3 Male Reference Connector for Female Enteral Testing

ISO 80369-3 Male Reference Connector for Female Enteral Testing

MOQ: 1
Price: To be quoted
Standard Packaging: safety carton pack or plywood box
Delivery Period: 7 working days
Payment Method: T/T
Supply Capacity: 50 pcs per month
Detail Information
Place of Origin
China
Brand Name
Kingpo
Certification
ISO 17025 calibration certificate
Model Number
ISO 80369-3-Figure C.3
Standard:
ISO 80369-3-Figure C.3
Material:
Hardness Steel
Hardness:
HRC58-62
Highlight:

ISO 80369-3 male connector

,

enteral testing reference connector

,

medical test equipment connector

Product Description
ISO 80369-3 Male Reference Connector for Female Enteral Testing
Product Specifications
Attribute Value
Standard ISO 80369-3-Figure C.3
Material Hardness Steel
Hardness HRC58-62
Product Description

The ISO 80369-3 Figure C.3 Male Reference Connector is a precision testing tool designed to evaluate female enteral connectors for compliance with ISO 80369-3 standards. This reference connector ensures proper testing of leakage, disconnection by unscrewing, separation from unscrewing, stress cracking, and non-interconnectable characteristics, guaranteeing safety and reliability in medical applications.

ISO 80369-3 Male Reference Connector for Female Enteral Testing 0
Key Features
  • Compliant with ISO 80369-3 Figure C.3 - Ensures accurate testing of female enteral connectors.
  • Leakage Testing - Validates seal integrity under pressure.
  • Disconnection & Separation Testing - Assesses resistance to accidental unscrewing.
  • Stress Cracking Evaluation - Detects material weaknesses under stress.
  • Non-Interconnectability Verification - Confirms incompatibility with wrong connector types.
Frequently Asked Questions
  • What is the ISO 80369-3 Figure C.3 Male Reference Connector used for?
    This connector is used for testing female enteral connectors to verify compliance with ISO 80369-3 standards, including leakage, disconnection, separation, stress cracking, and non-interconnectability.
  • How does this connector help prevent misconnections?
    The ISO 80369-3 standard ensures non-interconnectability with other medical connectors, reducing the risk of dangerous misconnections in healthcare settings.
  • Is this connector reusable?
    Yes, it is designed for multiple testing cycles, ensuring long-term reliability in quality control processes.
products
PRODUCTS DETAILS
ISO 80369-3 Male Reference Connector for Female Enteral Testing
MOQ: 1
Price: To be quoted
Standard Packaging: safety carton pack or plywood box
Delivery Period: 7 working days
Payment Method: T/T
Supply Capacity: 50 pcs per month
Detail Information
Place of Origin
China
Brand Name
Kingpo
Certification
ISO 17025 calibration certificate
Model Number
ISO 80369-3-Figure C.3
Standard:
ISO 80369-3-Figure C.3
Material:
Hardness Steel
Hardness:
HRC58-62
Minimum Order Quantity:
1
Price:
To be quoted
Packaging Details:
safety carton pack or plywood box
Delivery Time:
7 working days
Payment Terms:
T/T
Supply Ability:
50 pcs per month
Highlight

ISO 80369-3 male connector

,

enteral testing reference connector

,

medical test equipment connector

Product Description
ISO 80369-3 Male Reference Connector for Female Enteral Testing
Product Specifications
Attribute Value
Standard ISO 80369-3-Figure C.3
Material Hardness Steel
Hardness HRC58-62
Product Description

The ISO 80369-3 Figure C.3 Male Reference Connector is a precision testing tool designed to evaluate female enteral connectors for compliance with ISO 80369-3 standards. This reference connector ensures proper testing of leakage, disconnection by unscrewing, separation from unscrewing, stress cracking, and non-interconnectable characteristics, guaranteeing safety and reliability in medical applications.

ISO 80369-3 Male Reference Connector for Female Enteral Testing 0
Key Features
  • Compliant with ISO 80369-3 Figure C.3 - Ensures accurate testing of female enteral connectors.
  • Leakage Testing - Validates seal integrity under pressure.
  • Disconnection & Separation Testing - Assesses resistance to accidental unscrewing.
  • Stress Cracking Evaluation - Detects material weaknesses under stress.
  • Non-Interconnectability Verification - Confirms incompatibility with wrong connector types.
Frequently Asked Questions
  • What is the ISO 80369-3 Figure C.3 Male Reference Connector used for?
    This connector is used for testing female enteral connectors to verify compliance with ISO 80369-3 standards, including leakage, disconnection, separation, stress cracking, and non-interconnectability.
  • How does this connector help prevent misconnections?
    The ISO 80369-3 standard ensures non-interconnectability with other medical connectors, reducing the risk of dangerous misconnections in healthcare settings.
  • Is this connector reusable?
    Yes, it is designed for multiple testing cycles, ensuring long-term reliability in quality control processes.