IEC 62209-3 Fast SAR Automatic Measurement System,CSAR3D - SAR System With Novel Vector Array Technology

Certification
China KingPo Technology Development Limited certification
China KingPo Technology Development Limited certification
Customer Reviews
According to SGS Qualified Suppliers requirements. kingpo is granted as "STATEMENT OF SGS QUALIFED SUPPLIERS"

—— SGS

Good day and thank you for you According to the sample of the instrument you provided, we are very satisfied with our test. We want to change the order from 2 to 10. The following is the order details of our Asia Pacific branch. Would you please send me the quotation of the corresponding office? So we can generate an order to confirm it. Thank you.

—— Angel

Dear Supplier KINGPO TECHNOLOGY DEVELOPEMENT, In the ambit of ISO 9001:2015 certification, we intend to communicate the requirements as well as its percentage used on final evaluation used by ISQ to control and monitor its external supplier’s performance as per bellow: According with the above requirements to be maintained in future evaluations

—— ISQ Procurement Management

I'm Online Chat Now
Company News
IEC 62209-3 Fast SAR Automatic Measurement System,CSAR3D - SAR System With Novel Vector Array Technology
Latest company news about IEC 62209-3 Fast SAR Automatic Measurement System,CSAR3D - SAR System With Novel Vector Array Technology

IEC 62209-3 Fast SAR Automatic Measurement System,CSAR3D - SAR System With Novel Vector Array Technology

IEC 62209-3 Fast SAR Automatic Measurement System,CSAR3D - SAR System With Novel Vector Array Technology

SAR: the full English name of SAR is specific absorption rate, which is generally called electromagnetic wave absorption ratio or specific absorption rate in Chinese. It is the electromagnetic wave energy absorption ratio of mobile phone or wireless product, which is defined as: under the action of external electromagnetic field, induced electromagnetic field will be generated in human body. Since various organs of the human body are lossy media, the electromagnetic field in the body will produce current, resulting in the absorption and dissipation of electromagnetic energy. Specific absorption rate (SAR) test is a radio frequency (RF) dosimetry method to quantify the size and distribution of electromagnetic energy absorbed by biological objects exposed to RF field. Excessive exposure to RF energy will damage human tissues. In order to prevent this from happening, many countries in the world have introduced standards to limit the amount of RF radiation allowed by all types of transmitters. SAR is often used to characterize this physical process in biological dosimetry. The meaning of SAR is the electromagnetic power absorbed or consumed by human tissue per unit mass, in w / kg.

 

CCC test standard:

Standard: YD / t1644

Limit requirements: the SAR limit takes 10g average value, and the limit is 2.0w/kg.

 

CE test standard:

Test specification: EN62209-1:2016

Limit requirements: the SAR limit takes 10g average value, and the limit is 2.0w/kg.

 

FCC test standard:

The standards are: 47cfr part 2.1093, FCC OET bulletin 65 supply C, ANSI / IEEE C95.1 and c95.3, ANSI / IEEE P1528

Limit requirements: the SAR limit takes 1g as the unit to calculate the peak, and the limit is 1.6w/kg

IEC 62209-3 Fast SAR Automatic Measurement System,CSAR3D - SAR System With Novel Vector Array Technology 0

 

 

cSAR3D - SAR System with Novel Vector Array Technolog

Pub Time : 2021-10-24 21:36:42 >> News list