Home
Products
About Us
Factory Tour
Quality Control
Contact Us
Request A Quote
Home ProductsElectrical Safety Test Equipment

10A 3 Station IEC60335-1 Flexing Test Apparatus

Certification
China KingPo Technology Development Limited certification
China KingPo Technology Development Limited certification
Customer Reviews
Dear Supplier KINGPO TECHNOLOGY DEVELOPEMENT, In the ambit of ISO 9001:2015 certification, we intend to communicate the requirements as well as its percentage used on final evaluation used by ISQ to control and monitor its external supplier’s performance as per bellow: According with the above requirements to be maintained in future evaluations

—— ISQ Procurement Management

Good day and thank you for you According to the sample of the instrument you provided, we are very satisfied with our test. We want to change the order from 2 to 10. The following is the order details of our Asia Pacific branch. Would you please send me the quotation of the corresponding office? So we can generate an order to confirm it. Thank you.

—— Angel

I'm Online Chat Now

10A 3 Station IEC60335-1 Flexing Test Apparatus

10A 3 Station IEC60335-1 Flexing Test Apparatus
10A 3 Station IEC60335-1 Flexing Test Apparatus

Large Image :  10A 3 Station IEC60335-1 Flexing Test Apparatus

Product Details:
Place of Origin: China
Brand Name: Kingpo
Certification: Calibration Certificate
Model Number: KP-8869C
Payment & Shipping Terms:
Minimum Order Quantity: 1
Price: To be Quoted
Packaging Details: safety carton pack or plywood box
Delivery Time: 30 working days
Payment Terms: T/T
Supply Ability: 10 sets per month
Detailed Product Description
Standard: IEC60335 Fuse: 10A/250VAC
Number Of Sample Core: 3-core Test Station: 3
Fixture: Can Be Selected According To Need Inside: 0-25A
High Light:

3 Station Flexing Test Apparatus

,

10A Flexing Test Apparatus

 

IEC60884 Three Station Flexing Test Apparatus for Rocking Motion Testing of Plug Power Cords

 

 

Instrument Introduction

1.1 Main uses

This instrument is mainly used to test the flexural fatigue strength of AC power cords and plug leads. It is suitable for rocking motion testing of plug power cords under a certain load.

The instrument has no-load (only measures life, does not make open circuit judgment) On-off (makes open circuit judgment), external load (also equipped with load machine, L, N line with large current and voltage load, can make open circuit judgment), internal load test function.It has the advantages of reliable detection, stable operation, and the ability to test four products of the same type at the same time. It is an ideal instrument for the laboratory and quality control department to test related performances such as plug wires and connectors.

 

1.2 Design standards

This instrument complies with IEC60335-1 ,UL817, IEC60884, VDE0602, GB2099 and other standards.

 

1.3 Technical parameters

No. Items Specifications
  •  
Input power 220VAC±10%, 50/60Hz
  •  
fuse 10A/250VAC
  •  
Output Power 2000W
  •  
Number of sample cores 3-core
  •  
Test station Three station
  •  
Fixture Can be selected according to need
  •  
Inside 0-25A
  •  
External load 0-300V 0-20A
  •  
Bending angle ±(5°~ 180°)
  •  
Bending accuracy ±1°
  •  
Bending speed ±(5°~90°), 5~60 times/min arbitrary setting; ±(91°~180°), 5~40 times/min arbitrary setting
  •  
Testing frequency Arbitrary setting from 1 to 999999 times (error: ±1 time)
  •  
Failure alarm The buzzer alarms when the test sample line is broken, and the touch screen has a corresponding prompt
  •  
Qualification tips The sample to be tested bends to the set number of tests, the touch screen has corresponding prompts and warnings
  •  
Dimensions 1450 X 800 X 1400 (width X depth X height)
  •  
weight About 300 Kg

 

 

 

 

 

Installation Instructions

2.1 Disassembly and inspection

1. Check whether the instrument has been injured or damaged during transportation;

2. Check whether the instrument is upside down;

3. Check whether the specifications on the nameplate of the instrument are consistent with the order;

4. Check whether the packing list is consistent with the actual product.

If the above phenomenon occurs, please do not use the instrument and contact us in time.

 

2.2 Safety regulations

1. Before using the instrument, please read the manual carefully and understand the relevant safety signs and operating procedures to ensure safety.

2. Check whether the power supply voltage is consistent with the specifications provided on the nameplate. The power supply must be well grounded.

3. Non-professionals should not open the door or cover of the instrument to prevent electric shock.

4. The instrument panel display cannot be scratched with sharp objects.

5. The user must not change the circuit or parts of the instrument by himself, otherwise the quality guarantee will be invalid and suppllier will not be responsible for the consequences.

 

2.3 Installation requirements

1. The instrument should be placed on a level and stable work surface. If there is any unevenness, it should be adjusted first.

2. The ambient temperature used by this instrument is 25±10°C, and the relative humidity is 50±30%RH.

3. The instrument should be kept away from heat and corrosion sources.

4. The instrument is connected to a 220V/50Hz±10% power supply with good grounding.

 

10A 3 Station IEC60335-1 Flexing Test Apparatus 0

 

10A 3 Station IEC60335-1 Flexing Test Apparatus 1

 

10A 3 Station IEC60335-1 Flexing Test Apparatus 2

 

10A 3 Station IEC60335-1 Flexing Test Apparatus 3

 

10A 3 Station IEC60335-1 Flexing Test Apparatus 4

Contact Details
KingPo Technology Development Limited

Contact Person: Ms.Lynette Wong

Tel: +8613712225112

Send your inquiry directly to us (0 / 3000)