In medical device engineering, small-bore connector integrity is essential for patient safety and system reliability. ISO 80369-7:2021, "Small-bore connectors for liquids and gases in healthcare applications - Part 7: Connectors for intravascular or hypodermic applications," defines stringent dimensional and functional criteria for Luer connectors. This standard replaces ISO 594-1 and ISO 594-2, incorporating improved tolerances, material classifications, and testing protocols to minimize misconnections and leaks in vascular systems.
This technical overview examines ISO 80369-7:2021 in depth, emphasizing minimum standards for male reference plug gauges used to verify female Luer connectors. It includes technical specifications, gauge roles in compliance, key features, and quality assurance implications.
ISO released ISO 80369-7:2021 in May 2021 for 6% (Luer) taper small-bore connectors in intravascular or hypodermic applications. It covers slip and lock Luer designs, ensuring non-interconnectability with other ISO 80369 series to avoid cross-connections between different medical systems.
Revisions from 2016 include refined tolerances for manufacturability, distinctions between semi-rigid (700-3,433 MPa modulus) and rigid (>3,433 MPa) materials, and enhanced usability assessments. These align with ISO 80369 goals, stressing tests for fluid/air leakage, stress cracking, axial separation resistance, unscrewing torque, and overriding prevention.
Male reference plug gauges serve as "go/no-go" tools to evaluate female Luer connector dimensional accuracy and functional performance. They replicate the standard's conical taper and thread profiles to detect defects that could cause clinical issues.
Gauges assess taper conformity, thread compatibility, and seal efficacy under conditions like 300 kPa pressure. This is vital for intravenous therapy, hypodermic injections, and fluid delivery, where deviations may cause leaks or contamination.
Reputable manufacturers produce gauges from hardened steel (HRC 58-62) with ISO 17025 calibration for traceability. The 6% taper matches the standard's profile for non-interconnectability and performance testing requirements.
| Parameter | Specification |
|---|---|
| Place of Origin | China |
| Brand Name | Kingpo |
| Model Number | ISO 80369-7 |
| Standard | ISO 80369-7 |
| Material | Hardness Steel |
| Hardness | HRC 58-62 |
| Certification | ISO 17025 Calibration Certificate |
| Key Design Features | 6% taper; 300 kPa pressure rating |
ISO 80369-7:2021 specifies reference connectors as gauge benchmarks with the following critical requirements:
| Test Type | Requirement/Details | Minimum Performance |
|---|---|---|
| Fluid Leakage | Pressure decay or positive pressure method | No leakage |
| Sub-Atmospheric Air Leakage | Vacuum application | No leakage |
| Stress Cracking Resistance | Chemical exposure and load | No cracking |
| Resistance to Axial Separation | Slip: 35 N; Lock: 80 N (minimum hold) | Sustained for 15 s |
| Unscrewing Torque (Lock only) | Minimum torque to resist loosening | ≥ 0.08 N*m |
| Resistance to Overriding | Prevent thread damage during assembly | No overriding |
Using ISO 80369-7 gauges in protocols detects non-conformities early, lowering recall risks and aligning with FDA 21 CFR and EU MDR requirements. Functional testing ensures seals under stress, preventing clinical adverse events.
It defines Luer connector dimensions and performance for safe intravascular connections and misconnection prevention.
They evaluate dimensional accuracy, taper engagement, and performance against Annex C references, including leakage and separation testing.
ISO 80369-7 adds stricter tolerances, material classes, and integrated slip/lock testing, prioritizing non-interconnectability.
Hardened steel at HRC 58-62 ensures precision and durability for repeated testing.
It provides conical conformity for secure, leak-resistant fittings in hypodermic and IV systems.
Fluid/air leakage, stress cracking, axial resistance (35-80 N), unscrewing torque (≥0.08 N*m), and overriding prevention.
It separates semi-rigid and rigid requirements by modulus for design flexibility.
Suppliers like Kingpo, Enersol, and Medi-Luer offer calibrated products meeting standard requirements.
In summary, ISO 80369-7:2021 advances Luer connector standardization, with male reference plug gauges upholding dimensional and performance thresholds. These tools enable superior safety, compliance, and innovation in medical devices.
In medical device engineering, small-bore connector integrity is essential for patient safety and system reliability. ISO 80369-7:2021, "Small-bore connectors for liquids and gases in healthcare applications - Part 7: Connectors for intravascular or hypodermic applications," defines stringent dimensional and functional criteria for Luer connectors. This standard replaces ISO 594-1 and ISO 594-2, incorporating improved tolerances, material classifications, and testing protocols to minimize misconnections and leaks in vascular systems.
This technical overview examines ISO 80369-7:2021 in depth, emphasizing minimum standards for male reference plug gauges used to verify female Luer connectors. It includes technical specifications, gauge roles in compliance, key features, and quality assurance implications.
ISO released ISO 80369-7:2021 in May 2021 for 6% (Luer) taper small-bore connectors in intravascular or hypodermic applications. It covers slip and lock Luer designs, ensuring non-interconnectability with other ISO 80369 series to avoid cross-connections between different medical systems.
Revisions from 2016 include refined tolerances for manufacturability, distinctions between semi-rigid (700-3,433 MPa modulus) and rigid (>3,433 MPa) materials, and enhanced usability assessments. These align with ISO 80369 goals, stressing tests for fluid/air leakage, stress cracking, axial separation resistance, unscrewing torque, and overriding prevention.
Male reference plug gauges serve as "go/no-go" tools to evaluate female Luer connector dimensional accuracy and functional performance. They replicate the standard's conical taper and thread profiles to detect defects that could cause clinical issues.
Gauges assess taper conformity, thread compatibility, and seal efficacy under conditions like 300 kPa pressure. This is vital for intravenous therapy, hypodermic injections, and fluid delivery, where deviations may cause leaks or contamination.
Reputable manufacturers produce gauges from hardened steel (HRC 58-62) with ISO 17025 calibration for traceability. The 6% taper matches the standard's profile for non-interconnectability and performance testing requirements.
| Parameter | Specification |
|---|---|
| Place of Origin | China |
| Brand Name | Kingpo |
| Model Number | ISO 80369-7 |
| Standard | ISO 80369-7 |
| Material | Hardness Steel |
| Hardness | HRC 58-62 |
| Certification | ISO 17025 Calibration Certificate |
| Key Design Features | 6% taper; 300 kPa pressure rating |
ISO 80369-7:2021 specifies reference connectors as gauge benchmarks with the following critical requirements:
| Test Type | Requirement/Details | Minimum Performance |
|---|---|---|
| Fluid Leakage | Pressure decay or positive pressure method | No leakage |
| Sub-Atmospheric Air Leakage | Vacuum application | No leakage |
| Stress Cracking Resistance | Chemical exposure and load | No cracking |
| Resistance to Axial Separation | Slip: 35 N; Lock: 80 N (minimum hold) | Sustained for 15 s |
| Unscrewing Torque (Lock only) | Minimum torque to resist loosening | ≥ 0.08 N*m |
| Resistance to Overriding | Prevent thread damage during assembly | No overriding |
Using ISO 80369-7 gauges in protocols detects non-conformities early, lowering recall risks and aligning with FDA 21 CFR and EU MDR requirements. Functional testing ensures seals under stress, preventing clinical adverse events.
It defines Luer connector dimensions and performance for safe intravascular connections and misconnection prevention.
They evaluate dimensional accuracy, taper engagement, and performance against Annex C references, including leakage and separation testing.
ISO 80369-7 adds stricter tolerances, material classes, and integrated slip/lock testing, prioritizing non-interconnectability.
Hardened steel at HRC 58-62 ensures precision and durability for repeated testing.
It provides conical conformity for secure, leak-resistant fittings in hypodermic and IV systems.
Fluid/air leakage, stress cracking, axial resistance (35-80 N), unscrewing torque (≥0.08 N*m), and overriding prevention.
It separates semi-rigid and rigid requirements by modulus for design flexibility.
Suppliers like Kingpo, Enersol, and Medi-Luer offer calibrated products meeting standard requirements.
In summary, ISO 80369-7:2021 advances Luer connector standardization, with male reference plug gauges upholding dimensional and performance thresholds. These tools enable superior safety, compliance, and innovation in medical devices.