ISO 80369-7 Figure C.2 Male Reference Luer Slip Connector and C.4 Male Luer Reference Connector

Certification
China KingPo Technology Development Limited certification
China KingPo Technology Development Limited certification
Customer Reviews
According to SGS Qualified Suppliers requirements. kingpo is granted as "STATEMENT OF SGS QUALIFED SUPPLIERS"

—— SGS

Good day and thank you for you According to the sample of the instrument you provided, we are very satisfied with our test. We want to change the order from 2 to 10. The following is the order details of our Asia Pacific branch. Would you please send me the quotation of the corresponding office? So we can generate an order to confirm it. Thank you.

—— Angel

Dear Supplier KINGPO TECHNOLOGY DEVELOPEMENT, In the ambit of ISO 9001:2015 certification, we intend to communicate the requirements as well as its percentage used on final evaluation used by ISQ to control and monitor its external supplier’s performance as per bellow: According with the above requirements to be maintained in future evaluations

—— ISQ Procurement Management

first of all, I would also like to thank you for the good cooperation! We especially appreciate the fast service and that there is almost always a solution for our requests and problems. Thank you very much for this and all the best and continue a good cooperation also for 2022!

—— TUV Rheinland Germany

I'm Online Chat Now

ISO 80369-7 Figure C.2 Male Reference Luer Slip Connector and C.4 Male Luer Reference Connector

large.img.alt
large.img.alt

Large Image :  ISO 80369-7 Figure C.2 Male Reference Luer Slip Connector and C.4 Male Luer Reference Connector

Product Details:
Place of Origin: China
Brand Name: Kingpo
Certification: Certificate of ISO17025
Model Number: ISO 80369-7
Payment & Shipping Terms:
Minimum Order Quantity: 1
Price: To be quoted
Packaging Details: safety carton pack or plywood box
Delivery Time: 7 working days
Payment Terms: T/T
Supply Ability: 50 pcs per month
Detailed Product Description
Brand Name: Kingpo Material: Hardness Steel
Standard: ISO 80369-7 Hardness: HRC58-62
Warranty: 1 Year Test Purpose: Luer Needle And Syringe Testing
High Light:

ISO 80369-7 C.4 Male Luer Reference Connector

,

C.4 Male Luer Reference Connector

,

C.2 Male Reference Luer Slip Connector

ISO 80369-7 Figure C.2 Male Reference Luer Slip Connector and C.4 Male Luer Reference Connector
 
ISO 80369-7 C.4 Male Luer Reference Connector
 
Compatibility/Interchangeability:
Between ISO 594/2 Fig 7 and ISO 80369-7 Fig C.4
The ISO 594/2 Figure 7 Male Luer Reference Conical Fitting is replaced by ISO 80369-7 Fig C.4 Male Luer Reference Connector. The ISO 80369-7 Figure C.4 is identical to the ISO 594/2 Figure 7 Reference Fitting. ISO 80369-7 Fig C.4 and ISO 594/2 Fig 7 are completely interchangeable.
 
Design Details:
Keeping with the requirements of ISO 80369-7, the Reference Connectors we produce are from hardened stainless steel. The design details might vary by manufacturer so please communicate with us to make sure you understand the configuration before you place the order. The ISO 80369 Reference Connectors are an integral part of Luer needle and syringe testing.
 
It can perform tests:
The ISO 80369-7 Figure C.4 Male Luer Reference Connectors are used for testing Female Luer Connectors for: Leakage; Separation from unscrewing; Stress cracking; and Non-interconnectable characteristics in the ISO 80369-7; Clause 6 specified tests.
Below is the list of tests which are accomplished by using the ISO 80369-7 Fig C.4 Male Luer Reference Connector:
ISO 80369-7 Clause...
4.1: Non-Interconnectivity
6.1: Fluid Leakage
6.2: Sub-Atmospheric Pressure Air Leakage
6.3: Stress Cracking
6.5: Resistance To Separation From Unscrewing
 
ISO 80369-7 Fig C.2 Male Reference Luer Slip Connector
 
Compatibility/Interchangeability Between ISO 594/1 Figure 5 and ISO 80369-7 Figure C.2:
ISO 80369-7 Figure C.2 Male Reference Luer Slip Connector is 100% backward compatible with the ISO 594/1 Figure 5 Reference Fitting; so it can be certified and used in ISO 594/1 designated testing.
If you request a quote for a new ISO 594/1 Fig 5 Reference Connector from us; we will quote an item which will pass both ISO 594 and ISO 80369-7 requirements.
 
It can perform tests:
The ISO 80369-7 Fig C.2 Male Reference Luer Slip Connector is used for testing Female Luer Connectors for: Leakage; Separation from axial load; Stress cracking; and Non-interconnectable characteristics in the ISO 80369-7; Clause 6 specified tests.
 
Design Details:
Keeping with the requirements of ISO 80369-7,the Reference Connectors we produce are from hardened stainless steel.The design details might vary by manufacturer so please communicate with us to make sure you understand the configuration before you place the order. The ISO 80369-7 Fig C2 Male Reference Luer Slip Connector is an integral part of Luer needle and syringe testing.
 
 
 