Home
Products
About Us
Factory Tour
Quality Control
Contact Us
Request A Quote
News
Home ProductsElectrical Safety Test Equipment

EN 14543:2005+A1:2007 (E) Clause 7.2.2.2 Figure 1 Test Cone Protecting against accidental contact with the burner

Certification
China KingPo Technology Development Limited certification
China KingPo Technology Development Limited certification
Customer Reviews
According to SGS Qualified Suppliers requirements. kingpo is granted as "STATEMENT OF SGS QUALIFED SUPPLIERS"

—— SGS

Good day and thank you for you According to the sample of the instrument you provided, we are very satisfied with our test. We want to change the order from 2 to 10. The following is the order details of our Asia Pacific branch. Would you please send me the quotation of the corresponding office? So we can generate an order to confirm it. Thank you.

—— Angel

Dear Supplier KINGPO TECHNOLOGY DEVELOPEMENT, In the ambit of ISO 9001:2015 certification, we intend to communicate the requirements as well as its percentage used on final evaluation used by ISQ to control and monitor its external supplier’s performance as per bellow: According with the above requirements to be maintained in future evaluations

—— ISQ Procurement Management

first of all, I would also like to thank you for the good cooperation! We especially appreciate the fast service and that there is almost always a solution for our requests and problems. Thank you very much for this and all the best and continue a good cooperation also for 2022!

—— TUV Rheinland Germany

I'm Online Chat Now

EN 14543:2005+A1:2007 (E) Clause 7.2.2.2 Figure 1 Test Cone Protecting against accidental contact with the burner

EN 14543:2005+A1:2007 (E) Clause 7.2.2.2 Figure 1 Test Cone Protecting against accidental contact with the burner
EN 14543:2005+A1:2007 (E) Clause 7.2.2.2 Figure 1 Test Cone Protecting against accidental contact with the burner EN 14543:2005+A1:2007 (E) Clause 7.2.2.2 Figure 1 Test Cone Protecting against accidental contact with the burner EN 14543:2005+A1:2007 (E) Clause 7.2.2.2 Figure 1 Test Cone Protecting against accidental contact with the burner EN 14543:2005+A1:2007 (E) Clause 7.2.2.2 Figure 1 Test Cone Protecting against accidental contact with the burner

Large Image :  EN 14543:2005+A1:2007 (E) Clause 7.2.2.2 Figure 1 Test Cone Protecting against accidental contact with the burner

Product Details:
Place of Origin: China
Brand Name: KingPo
Certification: Calibration certificate
Payment & Shipping Terms:
Minimum Order Quantity: 1
Price: To be Quoted
Packaging Details: safety carton pack or plywood box.
Delivery Time: 10 working days
Payment Terms: T/T
Supply Ability: 30 pcs per month
Detailed Product Description
Standard: EN 14543:2005+A1:2007 (E) Clause 7.2.2.2 Application: Verification Of Compliance With Design Requirements
Test Sample: Heater Purpose: Protecting Against Accidental Contact With The Burner
Warranty: 1 Year Country Of Origin: China

 
EN 14543:2005+A1:2007 (E) Specification for dedicated liquefied petroleum gas appliances — Parasol patio heaters — Flueless radiant heaters for outdoor or amply ventilated area us
 
EN 14543:2005+A1:2007 (E) Clause 7.2.2.2 Figure 1 Test Cone Protecting against accidental contact with the burner
 
7.2.2.2 Test cone
The appliance is put into normal operation with the reference gas under Pn at the nominal heat input.The test cone illustrated in figure 1 is applied against the grid openings with a force of 5N.
 
EN 14543:2005+A1:2007 (E) Clause 7.2.2.2 Figure 1 Test Cone Protecting against accidental contact with the burner 0
 
 
The appliance is allowed to cool to ambient temperature and then positioned so that the plane of the central section of the grid is horizontal.
 
A load consisting of a flat of diameter 100mm and mass 5KG is placed on the grid,half-way between the securing points.Leave the load in place for 1 min then remove the load.The appliance is restarted to normal operation with the reference gas at Pn and reapply the test cone to the grid openings.
 
EN 14543:2005+A1:2007 (E) Clause 7.2.2.2 Figure 1 Test Cone Protecting against accidental contact with the burner 1
 
EN 14543:2005+A1:2007 (E) Clause 7.2.2.2 Figure 1 Test Cone Protecting against accidental contact with the burner 2
 

Contact Details
KingPo Technology Development Limited

Contact Person: Ms.Lynette Wong

Tel: +8613712225112

Send your inquiry directly to us (0 / 3000)