logo
Send Message
products
PRODUCTS DETAILS
Home > Products >
IEC60335-2-84 Ammonia and Hydrochloric Acid Test Chamber 0.055% Ammoniac 0-99999M Test Time

IEC60335-2-84 Ammonia and Hydrochloric Acid Test Chamber 0.055% Ammoniac 0-99999M Test Time

MOQ: 1
Price: to be quoted
Standard Packaging: plywood box
Delivery Period: 25 working days
Payment Method: T/T
Supply Capacity: 20 units per month
Detail Information
Place of Origin
CN
Brand Name
kingpo
Certification
ISO 17025 calibration certificate
Model Number
KP-35841
Standard:
IEC60335-2-84 Clause 31.101
Working Voltage:
220V 50Hz
Internal Dimension:
1200*1200*1200mm(w*d*h)
Ammoniac:
0.055%
Hydrochloric Acid:
0.0005%
Test Time:
0-99999M
Highlight:

IEC60335-2-84 Test Chamber

,

0.055% Ammoniac Test Chamber

,

Hydrochloric Acid Test Chamber

Product Description

IEC60335-2-84 Ammonia and Hydrochloric acid test chamber

 

Technical parameters:
Temperature range :RT to 50℃
2. Temperature accuracy :±1℃
3. Temperature uniformity: ±2.0℃
4. Test time: 0-99999 meters.
5. Equipment installation space: At least 3000×2000×2000mm(W×H×D)
6. Chamber Inner size: W1200*D1200*H1200mm
7. Power Supply :AC220V 50HZ
8. Ammonia concentration: adjustable from 0.01 to 0.1%
9. Hydrochloric acid concentration: adjustable from 0.0001 to 0.001
10. Chamber material: PP
10. Internal volume: 1728L
Structure
1. Material of the whole machine: The inner and outer boxes are made of pp acid and alkali resistant material and treated with insulation foaming
a. Glass rotor flowmeter: Precisely controlled by corrosion-resistant material
b. Relevant sealing joints and hardware :pp+ Teflon + titanium alloy +316L stainless steel
C. Chamber door material: 12mm tempered glass

2. Waste disposal system
A. It adopts a 40W high-volume air intake fan made in Taiwan and is equipped with an electric ball valve switch for conversion. Enable the waste gas inside the box to be discharged quickly.
B. Large-diameter spray pipes, combined with R20 and filter cotton, can filter over 90% of the waste gas
3. Heating system: Corrosion-resistant titanium alloy electric heating tubes. Prevent corrosion from all acidic and alkaline solutions
4. Temperature sensing system: Titanium alloy PT100 sensor is adopted
5. Airway system:
a. The entire machine is equipped with PTFE corrosion-resistant pipes and pipes
6. Control System:
The control system adopts a P.I.D controller for simultaneous temperature control

 

IEC60335-2-84 Ammonia and Hydrochloric Acid Test Chamber 0.055% Ammoniac 0-99999M Test Time 0

 

Contact Kingpo Technology:
Tel: +86 769 81627526
Email: sales@kingpo.hk
Website: www.kingpo.hk

 

 

products
PRODUCTS DETAILS
IEC60335-2-84 Ammonia and Hydrochloric Acid Test Chamber 0.055% Ammoniac 0-99999M Test Time
MOQ: 1
Price: to be quoted
Standard Packaging: plywood box
Delivery Period: 25 working days
Payment Method: T/T
Supply Capacity: 20 units per month
Detail Information
Place of Origin
CN
Brand Name
kingpo
Certification
ISO 17025 calibration certificate
Model Number
KP-35841
Standard:
IEC60335-2-84 Clause 31.101
Working Voltage:
220V 50Hz
Internal Dimension:
1200*1200*1200mm(w*d*h)
Ammoniac:
0.055%
Hydrochloric Acid:
0.0005%
Test Time:
0-99999M
Minimum Order Quantity:
1
Price:
to be quoted
Packaging Details:
plywood box
Delivery Time:
25 working days
Payment Terms:
T/T
Supply Ability:
20 units per month
Highlight

IEC60335-2-84 Test Chamber

,

0.055% Ammoniac Test Chamber

,

Hydrochloric Acid Test Chamber

Product Description

IEC60335-2-84 Ammonia and Hydrochloric acid test chamber

 

Technical parameters:
Temperature range :RT to 50℃
2. Temperature accuracy :±1℃
3. Temperature uniformity: ±2.0℃
4. Test time: 0-99999 meters.
5. Equipment installation space: At least 3000×2000×2000mm(W×H×D)
6. Chamber Inner size: W1200*D1200*H1200mm
7. Power Supply :AC220V 50HZ
8. Ammonia concentration: adjustable from 0.01 to 0.1%
9. Hydrochloric acid concentration: adjustable from 0.0001 to 0.001
10. Chamber material: PP
10. Internal volume: 1728L
Structure
1. Material of the whole machine: The inner and outer boxes are made of pp acid and alkali resistant material and treated with insulation foaming
a. Glass rotor flowmeter: Precisely controlled by corrosion-resistant material
b. Relevant sealing joints and hardware :pp+ Teflon + titanium alloy +316L stainless steel
C. Chamber door material: 12mm tempered glass

2. Waste disposal system
A. It adopts a 40W high-volume air intake fan made in Taiwan and is equipped with an electric ball valve switch for conversion. Enable the waste gas inside the box to be discharged quickly.
B. Large-diameter spray pipes, combined with R20 and filter cotton, can filter over 90% of the waste gas
3. Heating system: Corrosion-resistant titanium alloy electric heating tubes. Prevent corrosion from all acidic and alkaline solutions
4. Temperature sensing system: Titanium alloy PT100 sensor is adopted
5. Airway system:
a. The entire machine is equipped with PTFE corrosion-resistant pipes and pipes
6. Control System:
The control system adopts a P.I.D controller for simultaneous temperature control

 

IEC60335-2-84 Ammonia and Hydrochloric Acid Test Chamber 0.055% Ammoniac 0-99999M Test Time 0

 