Detail Information
Place of Origin
china
Brand Name
kingpo
Certification
iso9001 ce
Standard:
SASO 1858
Test Purpose:
Energy Efficiency Test Of Electric Water Heater
Laboratory Room:
L × W × H: 6800mm × 3800mm × 3200mm
Laboratory Door:
H× W: 2200mm × 1200mm
Highlight:

electrical safety analyzer

,

tv signal tester

Product Description
Electric Water Heater Laboratory Technical Solution
Product Specifications:
Standard SASO 1858
Test Purpose Energy efficiency test of electric water heater
Laboratory Room L × W × H: 6800mm × 3800mm × 3200mm
Laboratory Door H × W: 2200mm × 1200mm
Project Overview

The energy efficiency laboratory of the electric water heater is designed and constructed according to international standards and specifications for precise testing and measurement.

Product Test Standards
  • IEC 60379: Performance test method for domestic water storage electric water heaters
  • SASO 1858
Measurement and Control Accuracy
Measuring Point Sensor Data Collection System Accuracy
Ambient temperature HMT100 temperature point UT35A ±0.1℃
Environment humidity HMT100 humidity point UT35A ±0.1℃
Mixed water tank water temperature Pt100 Class A UT35A ±0.1℃
Inlet and outlet water temperature T-type thermocouple Class I GM10 ±0.1℃
Water flow Electromagnetic Flowmeter GM10 ±0.5%
Laboratory Capabilities

This laboratory is dedicated to comprehensive energy efficiency testing of electric water heaters, including:

  • 24h energy consumption coefficient
  • Hot water outlet rate detection
  • Heating experiment
  • Input power experiment
  • Insulation time test
  • Power consumption experiment
  • Water consumption experiment
  • High temperature and high humidity test
  • Low temperature test
  • Other performance testing items
Tested Machine Types
  • Hanging electric water heater
  • Vertical electric water heater
  • Fast-heating electric water heater

Detection capability: Can test 6 household electric water heaters simultaneously.

Infrastructure Plan
Performance (Energy Efficiency) Laboratory
  • Laboratory room dimensions: 6800mm × 3800mm × 3200mm
  • Constructed with high-density 100mm rock wool insulation board inside double-sided color steel plate
  • Laboratory door: 2200mm × 1200mm double-opening door with observation window
  • Lighting: Philips tri-proof fluorescent lamps (top-mounted installation)
  • Ground: Foamed 3mm stainless steel floor with good insulation and non-slip performance
  • Access control system installed
Working Conditions
  • Temperature: Adjustable from 10°C to 50°C
  • Humidity: 40% - 85% RH, stability ±3%
  • Wind speed: ≤0.25m/s with no obvious convection
Temperature Control Systems
Refrigeration and Heating System
  • Refrigeration: Water-cooled units with integrated design
  • Heating: Can be stopped when fan stops working, with overheating protection
  • Air duct: Reasonably designed with down inlet and return air
  • Defrosting: System equipped with automatic defrost function
Humidification System
  • Stainless steel humidification water tank
  • Automatic water level control with water shortage and overflow protection
  • Humidifier electrode heating with insulation measures
Water System Features
Constant Temperature Water Tank
  • 2000L capacity with stirring function
  • Highly polished 304 stainless steel construction
  • Water temperature range: 10°C - 35°C
  • Water pressure: Maximum design pressure of 1.2Mpa
  • Water flow: ≥20L/min at 0.3Mpa pressure
Laboratory Workstation Design
Converter Power Station
  • Two three-phase inverter power supplies
  • Capacity: 45kVA/unit
  • Voltage: 230V/415V (single-phase 5-300V adjustable)
  • Frequency: 47-63Hz adjustable
Test Hanger
  • 2 rows, single-sided hanging, 3 stations per row
  • Steel frame structure with 18 matte black paint
  • Load capacity: 500kg/station
  • Stainless steel hooks with adjustable spacing
Software System Features
Feature Description
Data Management Storage, export, review, statistics, analysis, and printing of test data
Sampling Period User-configurable from 5 to 60 seconds
Data Security Automatic test continuation after system restart
Remote Access Supports multi-user access with IEEE1851 standard interface
Multi-language Chinese and English versions with easy switching
System Security
  • Protection against leakage, overload, short circuit
  • Overheating alarm for heating tubes
  • Humidifier overflow and water shortage protection
  • High/low temperature alarms
  • Noise level ≤70dB under normal operation
Warranty and Service
Component Warranty Period
Purchase equipment 3 years
Homemade equipment 3 years
Laboratory infrastructure 3 years

Lifelong tracking maintenance and repair available after warranty period.

products
PRODUCTS DETAILS
SASO 1858 Electric Water Heater Energy Efficiency Test Lab
MOQ: 1
Price: To be Quoted
Standard Packaging: satety plastic tool box or plywood package.
Delivery Period: 4 months
Payment Method: T/T
Supply Capacity: 10 sets per year
Detail Information
Place of Origin
china
Brand Name
kingpo
Certification
iso9001 ce
Standard:
SASO 1858
Test Purpose:
Energy Efficiency Test Of Electric Water Heater
Laboratory Room:
L × W × H: 6800mm × 3800mm × 3200mm
Laboratory Door:
H× W: 2200mm × 1200mm
Minimum Order Quantity:
1
Price:
To be Quoted
Packaging Details:
satety plastic tool box or plywood package.
Delivery Time:
4 months
Payment Terms:
T/T
Supply Ability:
10 sets per year
Highlight

electrical safety analyzer

,

tv signal tester

Product Description
Electric Water Heater Laboratory Technical Solution
Product Specifications:
Standard SASO 1858
Test Purpose Energy efficiency test of electric water heater
Laboratory Room L × W × H: 6800mm × 3800mm × 3200mm
Laboratory Door H × W: 2200mm × 1200mm
Project Overview

The energy efficiency laboratory of the electric water heater is designed and constructed according to international standards and specifications for precise testing and measurement.

Product Test Standards
  • IEC 60379: Performance test method for domestic water storage electric water heaters
  • SASO 1858
Measurement and Control Accuracy
Measuring Point Sensor Data Collection System Accuracy
Ambient temperature HMT100 temperature point UT35A ±0.1℃
Environment humidity HMT100 humidity point UT35A ±0.1℃
Mixed water tank water temperature Pt100 Class A UT35A ±0.1℃
Inlet and outlet water temperature T-type thermocouple Class I GM10 ±0.1℃
Water flow Electromagnetic Flowmeter GM10 ±0.5%
Laboratory Capabilities

This laboratory is dedicated to comprehensive energy efficiency testing of electric water heaters, including:

  • 24h energy consumption coefficient
  • Hot water outlet rate detection
  • Heating experiment
  • Input power experiment
  • Insulation time test
  • Power consumption experiment
  • Water consumption experiment
  • High temperature and high humidity test
  • Low temperature test
  • Other performance testing items
Tested Machine Types
  • Hanging electric water heater
  • Vertical electric water heater
  • Fast-heating electric water heater

Detection capability: Can test 6 household electric water heaters simultaneously.

Infrastructure Plan
Performance (Energy Efficiency) Laboratory
  • Laboratory room dimensions: 6800mm × 3800mm × 3200mm
  • Constructed with high-density 100mm rock wool insulation board inside double-sided color steel plate
  • Laboratory door: 2200mm × 1200mm double-opening door with observation window
  • Lighting: Philips tri-proof fluorescent lamps (top-mounted installation)
  • Ground: Foamed 3mm stainless steel floor with good insulation and non-slip performance
  • Access control system installed
Working Conditions
  • Temperature: Adjustable from 10°C to 50°C
  • Humidity: 40% - 85% RH, stability ±3%
  • Wind speed: ≤0.25m/s with no obvious convection
Temperature Control Systems
Refrigeration and Heating System
  • Refrigeration: Water-cooled units with integrated design
  • Heating: Can be stopped when fan stops working, with overheating protection
  • Air duct: Reasonably designed with down inlet and return air
  • Defrosting: System equipped with automatic defrost function
Humidification System
  • Stainless steel humidification water tank
  • Automatic water level control with water shortage and overflow protection
  • Humidifier electrode heating with insulation measures
Water System Features
Constant Temperature Water Tank
  • 2000L capacity with stirring function
  • Highly polished 304 stainless steel construction
  • Water temperature range: 10°C - 35°C
  • Water pressure: Maximum design pressure of 1.2Mpa
  • Water flow: ≥20L/min at 0.3Mpa pressure
Laboratory Workstation Design
Converter Power Station
  • Two three-phase inverter power supplies
  • Capacity: 45kVA/unit
  • Voltage: 230V/415V (single-phase 5-300V adjustable)
  • Frequency: 47-63Hz adjustable
Test Hanger
  • 2 rows, single-sided hanging, 3 stations per row
  • Steel frame structure with 18 matte black paint
  • Load capacity: 500kg/station
  • Stainless steel hooks with adjustable spacing
Software System Features
Feature Description
Data Management Storage, export, review, statistics, analysis, and printing of test data
Sampling Period User-configurable from 5 to 60 seconds
Data Security Automatic test continuation after system restart
Remote Access Supports multi-user access with IEEE1851 standard interface
Multi-language Chinese and English versions with easy switching
System Security
  • Protection against leakage, overload, short circuit
  • Overheating alarm for heating tubes
  • Humidifier overflow and water shortage protection
  • High/low temperature alarms
  • Noise level ≤70dB under normal operation
Warranty and Service
Component Warranty Period
Purchase equipment 3 years
Homemade equipment 3 years
Laboratory infrastructure 3 years

Lifelong tracking maintenance and repair available after warranty period.