logo
Send Message
products
PRODUCTS DETAILS
Home > Products >
250VAC IEC60335-1 Flexing Test Apparatus 4 Station

250VAC IEC60335-1 Flexing Test Apparatus 4 Station

MOQ: 1
Price: To be Quoted
Standard Packaging: safety carton pack or plywood box
Delivery Period: 30 working days
Payment Method: T/T
Supply Capacity: 10 sets per month
Detail Information
Place of Origin
China
Brand Name
Kingpo
Certification
Calibration Certificate
Model Number
KP-8869C-4
Standard:
IEC60335
Fuse:
10A/250VAC
Number Of Sample Core:
3-core
Test Station:
4
Fixture:
Can Be Selected According To Need
Ending Angle:
±(5°~ 180°)
Highlight:

250VAC Flexing Test Apparatus

,

IEC 60335-1 Flexing Test Apparatus

Product Description

 

                                                                    4 Station Flexing Test Apparatus 

 

 

Instrument Introduction

1.1 Main uses

This instrument is mainly used to test the flexural fatigue strength of AC power cords and plug leads. It is suitable for rocking motion testing of plug power cords under a certain load.

The instrument has no-load (only measures life, does not make open circuit judgment) On-off (makes open circuit judgment), external load (also equipped with load machine, L, N line with large current and voltage load, can make open circuit judgment), internal load test function.It has the advantages of reliable detection, stable operation, and the ability to test four products of the same type at the same time. It is an ideal instrument for the laboratory and quality control department to test related performances such as plug wires and connectors.

 

1.2 Design standards

This instrument complies with IEC60335 ,UL817, IEC60884, VDE0602, GB2099 and other standards.

 

1.3 Technical parameters

No. Items Specifications

1

Input power 220VAC±10%, 50/60Hz

2

fuse 10A/250VAC

3

Output Power 2000W

4

Number of sample cores 3-core

5

Test station 4 station

6

Fixture Can be selected according to need

7

Inside 0-25A

8

External load 0-300V 0-20A

9

Bending angle ±(5°~ 180°)

10

Bending accuracy ±0.5°

11

Bending speed ±(5°~90°), 5~60 times/min arbitrary setting; ±(91°~180°), 5~40 times/min arbitrary setting

12

Testing frequency Arbitrary setting from 1 to 999999 times (error: ±0.1 time)

13

Failure alarm The buzzer alarms when the test sample line is broken, and the touch screen has a corresponding prompt

14

Qualification tips The sample to be tested bends to the set number of tests, the touch screen has corresponding prompts and warnings

15

Dimensions 1450 X 800 X 1400 (width X depth X height)

16

weight About 300 Kg

 

 

 

 

 

Installation Instructions

2.1 Disassembly and inspection

1. Check whether the instrument has been injured or damaged during transportation;

2. Check whether the instrument is upside down;

3. Check whether the specifications on the nameplate of the instrument are consistent with the order;

4. Check whether the packing list is consistent with the actual product.

If the above phenomenon occurs, please do not use the instrument and contact us in time.

 

2.2 Safety regulations

1. Before using the instrument, please read the manual carefully and understand the relevant safety signs and operating procedures to ensure safety.

2. Check whether the power supply voltage is consistent with the specifications provided on the nameplate. The power supply must be well grounded.

3. Non-professionals should not open the door or cover of the instrument to prevent electric shock.

4. The instrument panel display cannot be scratched with sharp objects.

5. The user must not change the circuit or parts of the instrument by himself, otherwise the quality guarantee will be invalid and suppllier will not be responsible for the consequences.

 

2.3 Installation requirements

1. The instrument should be placed on a level and stable work surface. If there is any unevenness, it should be adjusted first.

2. The ambient temperature used by this instrument is 25±10°C, and the relative humidity is 50±30%RH.

3. The instrument should be kept away from heat and corrosion sources.

4. The instrument is connected to a 220V/50Hz±10% power supply with good grounding.

 

 

 

250VAC IEC60335-1 Flexing Test Apparatus 4 Station 0

 

250VAC IEC60335-1 Flexing Test Apparatus 4 Station 1

 

250VAC IEC60335-1 Flexing Test Apparatus 4 Station 2

 

250VAC IEC60335-1 Flexing Test Apparatus 4 Station 3

products
PRODUCTS DETAILS
250VAC IEC60335-1 Flexing Test Apparatus 4 Station
MOQ: 1
Price: To be Quoted
Standard Packaging: safety carton pack or plywood box
Delivery Period: 30 working days
Payment Method: T/T
Supply Capacity: 10 sets per month
Detail Information
Place of Origin
China
Brand Name
Kingpo
Certification
Calibration Certificate
Model Number
KP-8869C-4
Standard:
IEC60335
Fuse:
10A/250VAC
Number Of Sample Core:
3-core
Test Station:
4
Fixture:
Can Be Selected According To Need
Ending Angle:
±(5°~ 180°)
Minimum Order Quantity:
1
Price:
To be Quoted
Packaging Details:
safety carton pack or plywood box
Delivery Time:
30 working days
Payment Terms:
T/T
Supply Ability:
10 sets per month
Highlight

250VAC Flexing Test Apparatus

,

IEC 60335-1 Flexing Test Apparatus

Product Description

 

                                                                    4 Station Flexing Test Apparatus 

 

 

Instrument Introduction

1.1 Main uses

This instrument is mainly used to test the flexural fatigue strength of AC power cords and plug leads. It is suitable for rocking motion testing of plug power cords under a certain load.

The instrument has no-load (only measures life, does not make open circuit judgment) On-off (makes open circuit judgment), external load (also equipped with load machine, L, N line with large current and voltage load, can make open circuit judgment), internal load test function.It has the advantages of reliable detection, stable operation, and the ability to test four products of the same type at the same time. It is an ideal instrument for the laboratory and quality control department to test related performances such as plug wires and connectors.

 

1.2 Design standards

This instrument complies with IEC60335 ,UL817, IEC60884, VDE0602, GB2099 and other standards.

 

1.3 Technical parameters

No. Items Specifications

1

Input power 220VAC±10%, 50/60Hz

2

fuse 10A/250VAC

3

Output Power 2000W

4

Number of sample cores 3-core

5

Test station 4 station

6

Fixture Can be selected according to need

7

Inside 0-25A

8

External load 0-300V 0-20A

9

Bending angle ±(5°~ 180°)

10

Bending accuracy ±0.5°

11

Bending speed ±(5°~90°), 5~60 times/min arbitrary setting; ±(91°~180°), 5~40 times/min arbitrary setting

12

Testing frequency Arbitrary setting from 1 to 999999 times (error: ±0.1 time)

13

Failure alarm The buzzer alarms when the test sample line is broken, and the touch screen has a corresponding prompt

14

Qualification tips The sample to be tested bends to the set number of tests, the touch screen has corresponding prompts and warnings

15

Dimensions 1450 X 800 X 1400 (width X depth X height)

16

weight About 300 Kg

 

 

 

 

 

Installation Instructions

2.1 Disassembly and inspection

1. Check whether the instrument has been injured or damaged during transportation;

2. Check whether the instrument is upside down;

3. Check whether the specifications on the nameplate of the instrument are consistent with the order;

4. Check whether the packing list is consistent with the actual product.

If the above phenomenon occurs, please do not use the instrument and contact us in time.

 

2.2 Safety regulations

1. Before using the instrument, please read the manual carefully and understand the relevant safety signs and operating procedures to ensure safety.

2. Check whether the power supply voltage is consistent with the specifications provided on the nameplate. The power supply must be well grounded.

3. Non-professionals should not open the door or cover of the instrument to prevent electric shock.

4. The instrument panel display cannot be scratched with sharp objects.

5. The user must not change the circuit or parts of the instrument by himself, otherwise the quality guarantee will be invalid and suppllier will not be responsible for the consequences.

 

2.3 Installation requirements

1. The instrument should be placed on a level and stable work surface. If there is any unevenness, it should be adjusted first.

2. The ambient temperature used by this instrument is 25±10°C, and the relative humidity is 50±30%RH.

3. The instrument should be kept away from heat and corrosion sources.

4. The instrument is connected to a 220V/50Hz±10% power supply with good grounding.

 

 

 

250VAC IEC60335-1 Flexing Test Apparatus 4 Station 0

 

250VAC IEC60335-1 Flexing Test Apparatus 4 Station 1

 

250VAC IEC60335-1 Flexing Test Apparatus 4 Station 2

 

250VAC IEC60335-1 Flexing Test Apparatus 4 Station 3