IEC60745-2-5 Circular Saw Switch Endurance And Lower Guard Recovery Time Test Device

IEC60745-2-5 Circular Saw Switch Endurance And Lower Guard Recovery Time Test Device

MOQ: 1
Price: To be quoted
Standard Packaging: safety carton pack or plywood box.
Delivery Period: 20-25 working days
Payment Method: 100% T/T in advance
Supply Capacity: 50 sets/month
Detail Information
Place of Origin
Mainland China
Brand Name
kingpo
Certification
calibration certificates
Model Number
YW-1185
Standards:
IEC60745-2-5, EN 60745-2-5: 2010
Power Supply:
220V/50HZ
Electrical Control:
Mitsubishi 7-inch Touch Screen PLC Operation
Drive:
Motor Driven
Size:
80*70*100cm
Weight:
80kg
Highlight:

Circular Saw Switch Endurance Test Device

,

Circular Sa Recovery Time Test Device

,

IEC60745-2-5 Durability Testing Device

Product Description
IEC60745-2-5 Circular Saw Switch Endurance And Lower Guard Recovery Time Test Device
 
Comply with standards: EN 60745-2-5: 2010 Annex M21.18, Annex M21.18.301, Annex M21.203, Annex M21.301, figure M.301, IEC60745-2-5:2003 Annex BB.20.102, EN 60745-2-5:2010 clause 17.101 and clause 19.102.3.
 
Model:YW-1185
 
Purpose: Test the mechanical strength, durability test and recovery time test of the lower protective cover.
 
Sample range: circular saw
 
Structure and function: The circular saw is set to cut at 90°, showing a horizontal position. The lower protective cover repeats the cycle from fully closed to fully open, releasing 50,000 times at a rate of not less than 10 cycles per minute.the number of times recorded by the position sensor.
After the cycle operation, the response time of the lower protective cover is not more than 0.3s. If it exceeds 0.3s, the number of timeouts will be counted once. After the equipment runs for the number of tests, record the recovery time of the last lower protective cover, and the equipment automatically shuts down.
 
Technical Parameter:
No.
Items
parameter
remark
1
power supply
220V/50HZ
 
2
Electrical control
Mitsubishi PLC operation, 7-inch touch screen operation
 
3
drive
motor driven
 
4
Number of test
0-999999 times, can be preset
 
5
Detection time
0-9.99s, can be displayed
recovery time
6
Auto/manual speed
0-30°times/minute, can be preset
 
7
Manual state rotate clockwise/counterclockwise
Touch control
 
8
size and weight
80*70*100cm, weighs about 80kg;
 
 
 
 
 

 

 
 
 

products
PRODUCTS DETAILS
IEC60745-2-5 Circular Saw Switch Endurance And Lower Guard Recovery Time Test Device
MOQ: 1
Price: To be quoted
Standard Packaging: safety carton pack or plywood box.
Delivery Period: 20-25 working days
Payment Method: 100% T/T in advance
Supply Capacity: 50 sets/month
Detail Information
Place of Origin
Mainland China
Brand Name
kingpo
Certification
calibration certificates
Model Number
YW-1185
Standards:
IEC60745-2-5, EN 60745-2-5: 2010
Power Supply:
220V/50HZ
Electrical Control:
Mitsubishi 7-inch Touch Screen PLC Operation
Drive:
Motor Driven
Size:
80*70*100cm
Weight:
80kg
Minimum Order Quantity:
1
Price:
To be quoted
Packaging Details:
safety carton pack or plywood box.
Delivery Time:
20-25 working days
Payment Terms:
100% T/T in advance
Supply Ability:
50 sets/month
Highlight

Circular Saw Switch Endurance Test Device

,

Circular Sa Recovery Time Test Device

,

IEC60745-2-5 Durability Testing Device

Product Description
IEC60745-2-5 Circular Saw Switch Endurance And Lower Guard Recovery Time Test Device
 
Comply with standards: EN 60745-2-5: 2010 Annex M21.18, Annex M21.18.301, Annex M21.203, Annex M21.301, figure M.301, IEC60745-2-5:2003 Annex BB.20.102, EN 60745-2-5:2010 clause 17.101 and clause 19.102.3.
 
Model:YW-1185
 
Purpose: Test the mechanical strength, durability test and recovery time test of the lower protective cover.
 
Sample range: circular saw
 
Structure and function: The circular saw is set to cut at 90°, showing a horizontal position. The lower protective cover repeats the cycle from fully closed to fully open, releasing 50,000 times at a rate of not less than 10 cycles per minute.the number of times recorded by the position sensor.
After the cycle operation, the response time of the lower protective cover is not more than 0.3s. If it exceeds 0.3s, the number of timeouts will be counted once. After the equipment runs for the number of tests, record the recovery time of the last lower protective cover, and the equipment automatically shuts down.
 
Technical Parameter:
No.
Items
parameter
remark
1
power supply
220V/50HZ
 
2
Electrical control
Mitsubishi PLC operation, 7-inch touch screen operation
 
3
drive
motor driven
 
4
Number of test
0-999999 times, can be preset
 
5
Detection time
0-9.99s, can be displayed
recovery time
6
Auto/manual speed
0-30°times/minute, can be preset
 
7
Manual state rotate clockwise/counterclockwise
Touch control
 
8
size and weight
80*70*100cm, weighs about 80kg;