IEC62368 Pulse Test Generator (Figure D.1)

IEC62368 Pulse Test Generator (Figure D.1)

MOQ: 1
Price: 80000
Standard Packaging: 500*600*300
Payment Method: T/T
Detail Information
Place of Origin
china
Brand Name
kingpo
Certification
iso9001 ce
Model Number
PMR65
Highlight:

IEC62368 Pulse Test Generator

,

Figure D.1 Pulse Test Generator

,

Pulse Test Generator Equipment

Product Description

1. Product Name: pulse test generator

2. Product model:KP-PRM65

3. Standard basis:IEC62368-1:2018 Appendix D and figure D.1

4. Product introduction:

The pulse test generator is manufactured according to the requirements of Appendix D and figure D.1 of iec62368-1.

5. Standard requirements

IEC62368 Pulse Test Generator (Figure D.1) 0

Circuit type Test pulse C1 C2 R1 R2 R3
1 10/700us 20uF 0.2uF 50Ω 15Ω 25Ω
2 1.2/50us 1uF 30nF 76Ω 13Ω 25Ω
remarks

If the same results can be obtained, an alternative test generator can be used.

Note: circuit 1 and circuit 2 are based on ITU-T Recommendation K.44

products
PRODUCTS DETAILS
IEC62368 Pulse Test Generator (Figure D.1)
MOQ: 1
Price: 80000
Standard Packaging: 500*600*300
Payment Method: T/T
Detail Information
Place of Origin
china
Brand Name
kingpo
Certification
iso9001 ce
Model Number
PMR65
Minimum Order Quantity:
1
Price:
80000
Packaging Details:
500*600*300
Payment Terms:
T/T
Highlight

IEC62368 Pulse Test Generator

,

Figure D.1 Pulse Test Generator

,

Pulse Test Generator Equipment

Product Description

1. Product Name: pulse test generator

2. Product model:KP-PRM65

3. Standard basis:IEC62368-1:2018 Appendix D and figure D.1

4. Product introduction:

The pulse test generator is manufactured according to the requirements of Appendix D and figure D.1 of iec62368-1.

5. Standard requirements

IEC62368 Pulse Test Generator (Figure D.1) 0

Circuit type Test pulse C1 C2 R1 R2 R3
1 10/700us 20uF 0.2uF 50Ω 15Ω 25Ω
2 1.2/50us 1uF 30nF 76Ω 13Ω 25Ω
remarks

If the same results can be obtained, an alternative test generator can be used.

Note: circuit 1 and circuit 2 are based on ITU-T Recommendation K.44