Home
Products
About Us
Factory Tour
Quality Control
Contact Us
Request A Quote
News
Home ProductsMedical Test Equipment

IEC60601-1-Figure 33 IEC60601-Clause 9.8.3.3 Load Tester With MITSUBISHI PLC

Certification
China KingPo Technology Development Limited certification
China KingPo Technology Development Limited certification
Customer Reviews
According to SGS Qualified Suppliers requirements. kingpo is granted as "STATEMENT OF SGS QUALIFED SUPPLIERS"

—— SGS

Good day and thank you for you According to the sample of the instrument you provided, we are very satisfied with our test. We want to change the order from 2 to 10. The following is the order details of our Asia Pacific branch. Would you please send me the quotation of the corresponding office? So we can generate an order to confirm it. Thank you.

—— Angel

Dear Supplier KINGPO TECHNOLOGY DEVELOPEMENT, In the ambit of ISO 9001:2015 certification, we intend to communicate the requirements as well as its percentage used on final evaluation used by ISQ to control and monitor its external supplier’s performance as per bellow: According with the above requirements to be maintained in future evaluations

—— ISQ Procurement Management

first of all, I would also like to thank you for the good cooperation! We especially appreciate the fast service and that there is almost always a solution for our requests and problems. Thank you very much for this and all the best and continue a good cooperation also for 2022!

—— TUV Rheinland Germany

I'm Online Chat Now

IEC60601-1-Figure 33 IEC60601-Clause 9.8.3.3 Load Tester With MITSUBISHI PLC

large.img.alt
small.img.alt small.img.alt small.img.alt small.img.alt

Large Image :  IEC60601-1-Figure 33 IEC60601-Clause 9.8.3.3 Load Tester With MITSUBISHI PLC

Product Details:
Place of Origin: China
Brand Name: Kingpo
Certification: Certificate of ISO17025
Model Number: IEC60601-1-Figure 33
Payment & Shipping Terms:
Minimum Order Quantity: 1
Price: To be quoted
Packaging Details: safety carton pack or plywood box
Delivery Time: 7 working days
Payment Terms: T/T
Supply Ability: 10 pcs per month
Detailed Product Description
Brand Name: Kingpo Material: Foam
Standard: IEC60601-clause 9.8.3.3 Warranty: 1 Year
High Light:

IEC60601-Clause 9.8.3.3 Load Tester

,

IEC60601-1-Figure 33 Load Tester

,

MITSUBISHI PLC Load Testing Equipment

Body Upper-Carriage Module-IEC60601-1-Figure 33 , IEC60601-clause 9.8.3.3 loading tester

 

9.8.3.3 * Dynamic forces due to loading from persons
Where dynamic forces (due to sitting down, standing up, PATIENT handling PROCESS or the like) can be exerted on ME equipment parts intended to support or suspend a PATIENT or OPERATOR in NORMAL USE, the ME EQUIPMENT shall maintain BASIC SAFETY and ESSENTIAL
PERFORMANCE.
Compliance is checked by the following test:
Prior to performing this test, the PATIENT support/suspension system is positioned horizontally in its most disadvantageous position in NORMAL USE.
For the area of support/suspension where a PATIENT or OPERATOR can sit, the top reservoir of the body upper-carriage module described in Figure 33 is loaded with the appropriate mass to obtain the SAFE WORKING LOAD representing the PATIENT or OPERATOR as defined in the ACCOMPANYING DOCUMENTS. The body upper-carriage module with appropriate mass is dropped from a distance of 150 mm from the lowest edge of the foam to the area where a PATIENT or OPERATOR can sit. BASIC SAFETY and ESSENTIAL PERFORMANCE shall be maintained.


NOTE Examples of damage that can affect BASIC SAFETY include the reduction of CREEPAGE DISTANCES and AIR CLEARANCES below those specified in 8.9, access to parts that exceed limits in 8.4, or access to moving parts which could cause HARM.
Assessment criteria that can be useful in determining if this test has resulted in a loss of BASIC SAFETY include:
– those in Clause 8 and 11.6;
– the dielectric strength test as specified in 8.8.3 to evaluate the integrity of solid providing a MEANS OF PROTECTION; and
– measurement of CREEPAGE DISTANCES or AIR CLEARANCES to compare the values with the minimum distances
specified in 8.9. Small chips that do not adversely affect the protection against electric shock or moisture can
normally be ignored.

Body upper-carriage module

IEC60601-1-Figure 33 IEC60601-Clause 9.8.3.3 Load Tester With MITSUBISHI PLC 0

 

Parameters:

 

Model KP-601A
Name loading tester
Drop height 150 mm
Test sample size 1700(H)*1200(W)mm Max
Load weight 200kg Max (by adding steel balls)
Electrical control MITSUBISHI PLC, 7 Inch Touch screen
Power supply 220V 50HZ
ISO17025 Certificates test report issued by internationally recognized laboratory with ilac.MRA mark.

Equipment picture

IEC60601-1-Figure 33 IEC60601-Clause 9.8.3.3 Load Tester With MITSUBISHI PLC 1

IEC60601-1-Figure 33 IEC60601-Clause 9.8.3.3 Load Tester With MITSUBISHI PLC 2

Contact Details
KingPo Technology Development Limited

Contact Person: Ms.Lynette Wong

Tel: +8613712225112

Send your inquiry directly to us (0 / 3000)