Home
Products
About Us
Factory Tour
Quality Control
Contact Us
Request A Quote
News
Home ProductsPlug Socket Tester

Securement Of Pins Australian/NZ Plugs And Socket Outlets AS/NZS 3112:2017 Test

Certification
China KingPo Technology Development Limited certification
China KingPo Technology Development Limited certification
Customer Reviews
According to SGS Qualified Suppliers requirements. kingpo is granted as "STATEMENT OF SGS QUALIFED SUPPLIERS"

—— SGS

Good day and thank you for you According to the sample of the instrument you provided, we are very satisfied with our test. We want to change the order from 2 to 10. The following is the order details of our Asia Pacific branch. Would you please send me the quotation of the corresponding office? So we can generate an order to confirm it. Thank you.

—— Angel

Dear Supplier KINGPO TECHNOLOGY DEVELOPEMENT, In the ambit of ISO 9001:2015 certification, we intend to communicate the requirements as well as its percentage used on final evaluation used by ISQ to control and monitor its external supplier’s performance as per bellow: According with the above requirements to be maintained in future evaluations

—— ISQ Procurement Management

first of all, I would also like to thank you for the good cooperation! We especially appreciate the fast service and that there is almost always a solution for our requests and problems. Thank you very much for this and all the best and continue a good cooperation also for 2022!

—— TUV Rheinland Germany

I'm Online Chat Now

Securement Of Pins Australian/NZ Plugs And Socket Outlets AS/NZS 3112:2017 Test

Securement Of Pins Australian/NZ Plugs And Socket Outlets AS/NZS 3112:2017 Test
Securement Of Pins Australian/NZ Plugs And Socket Outlets AS/NZS 3112:2017 Test Securement Of Pins Australian/NZ Plugs And Socket Outlets AS/NZS 3112:2017 Test Securement Of Pins Australian/NZ Plugs And Socket Outlets AS/NZS 3112:2017 Test Securement Of Pins Australian/NZ Plugs And Socket Outlets AS/NZS 3112:2017 Test Securement Of Pins Australian/NZ Plugs And Socket Outlets AS/NZS 3112:2017 Test

Large Image :  Securement Of Pins Australian/NZ Plugs And Socket Outlets AS/NZS 3112:2017 Test

Product Details:
Place of Origin: China
Brand Name: KingPo
Certification: Calibration certificate
Payment & Shipping Terms:
Minimum Order Quantity: 1
Price: To be Quoted
Packaging Details: safety carton pack or plywood box.
Delivery Time: 30 working days
Payment Terms: T/T
Supply Ability: 10 sets per month
Detailed Product Description
Standard: AS/NZS 3112:2017 Clause 2.13.9 Application: Securement Of Pins
Test Sample: Australian/NZ Plugs And Socket-outlets Precondition: Needed
Force Applied: 18 ±1 N Warranty: 1 Year
High Light:

NZ Plugs And Socket Outlets

,

Calibration Certificate Plugs And Socket Outlets

,

Calibration Plugs And Socket Outlets

AS/NZS 3112:2017 Test Device for Securement of pins for Australian/NZ Plugs and socket-outlets
AS/NZS 3112:2017 Clause 2.13.9 Test Device for Securement of pins
 
2.13.9 Securement of pins
2.13.9.1 Movement of pins
   Plugs shall be tested for pin movement by clamping the pin or pins not under test in a rigid holding block positioned 5 ±0.5 mm from the plug face and applying a force of 18 ±1 N to the pin under test. The design of the block shall be such that the pin under test shall not
come into contact with the block during the test.
 
   Except for non-rewireable plugs, the test shall be carried out without a cord attached to the plug, and with the terminal screws loosened sufficiently to allow a 1 mm2 conductor to be connected.
 
   The plug and test equipment shall be preconditioned at a temperature of 40 ±1°C for 1 h,without the test force applied. Throughout the test, all parts of the plug and test equipment shall be maintained at this temperature.
 
   For all plugs, the point of application of the force shall be 14 ±0.5 mm from the face of the plug along the pins, and the direction of the force shall be—
  (a) in both directions along the line perpendicular to the plane of the pin, and passing
through the centre of the pin; and
  (b) in that plane in both directions along a line at right angles to that specified in
Item (a).
 
   Over a period of 10 s, the force shall be gradually applied to each of the pins in the manner prescribed in Items (a) and (b), maintained at its maximum value for 10 s, and then released. The deflection of the pins shall be measured along the line of force relative to the
face of the rigid holding block during the period when the force is applied. The maximum deflection shall not exceed 2.0 mm.
 
   Following the test on all pins of a plug conforming to Figure 2.1, any distortion 5 min after the completion of the test on the last pin shall be such that it will not prevent the plug from being inserted in the appropriate standard gauges shown in Appendix A, Appendix B and
Appendix F without the application of undue force.
 
   For other types of plugs, any distortion after 5 min shall be such that will not prevent the plug being inserted into an appropriate socket-outlet without the application of undue force.
 
Securement Of Pins Australian/NZ Plugs And Socket Outlets AS/NZS 3112:2017 Test 0
 
Securement Of Pins Australian/NZ Plugs And Socket Outlets AS/NZS 3112:2017 Test 1
Securement Of Pins Australian/NZ Plugs And Socket Outlets AS/NZS 3112:2017 Test 2
 
 

Contact Details
KingPo Technology Development Limited

Contact Person: Ms.Lynette Wong

Tel: +8613712225112

Send your inquiry directly to us (0 / 3000)