A2L Refrigerant Flame-Retardant Enclosure Test Machine Compliant with IEC 60335-2-40:2022 and GB/T 4706.32-2024 Featuring Adjustable 0.5-10mm Electrode Spark Gap

A2L Refrigerant Flame-Retardant Enclosure Test Machine Compliant with IEC 60335-2-40:2022 and GB/T 4706.32-2024 Featuring Adjustable 0.5-10mm Electrode Spark Gap

MOQ: 1
Price: To be quoted
Standard Packaging: safety carton pack or plywood box
Payment Method: T/T
Detail Information
Place of Origin
China
Brand Name
Kingpo
Certification
ISO 17025
Model Number
KP-FT3541
Standards:
IEC 60335-2-40:2022 And GB/T 4706.32-2024
Electrode Spark Gap:
0.5-10mm Adjustable
Transformer Voltage Range:
0-20KV, Resolution 1V
Discharge Time:
0.3s ± 0.05s
Highlight:

IEC 60335-2-40:2022 Compliant Flame Test Equipment

,

GB/T 4706.32-2024 Compliant A2L Refrigerant Test Chamber

,

Adjustable Electrode Spark Gap Flame-Retardant Enclosure Test Machine

Product Description
A2L Refrigerant Flame-Retardant Enclosure Verification Test Machine
Product Overview
The flame-retardant enclosure verification test chamber for A2L refrigerant is designed to test and verify the flame-retardant effect of enclosures during A2L refrigerant leakage scenarios. This equipment complies with IEC 60335-2-40:2022 and GB/T 4706.32-2024 standards, simulating refrigerant leakage to evaluate enclosure flame-retardant performance.
Equipment Functions and Standards
Designed according to international standards IEC 60335-2-40:2022 and GB/T 4706.32-2024, this testing machine is suitable for household appliances including electric heat pumps, air conditioners, and dehumidifiers.
  • Simulates refrigerant leakage scenarios to test flame-retardant enclosure effectiveness
  • Verifies whether the enclosure can effectively prevent flame spread after leakage
Equipment Composition
  • High-voltage spark generator (1 set)
  • Explosion-proof simulated environment chamber (1 set)
  • Control system (1 set)
Technical Parameters
Component Specification
High-voltage spark generator Included in system
Electrode Spark Gap 0.5-10mm adjustable
Transformer Voltage Range 0-20KV, resolution 1V
Discharge Time 0.3s ± 0.05s
Discharge Quantity 30mA; Resolution: 0.01mA
Dry Bulb Humidity 32℃ (adjustable)
Dew Point Temperature 27℃ (adjustable)
Voltage Input 220VAC
Products
PRODUCTS DETAILS
A2L Refrigerant Flame-Retardant Enclosure Test Machine Compliant with IEC 60335-2-40:2022 and GB/T 4706.32-2024 Featuring Adjustable 0.5-10mm Electrode Spark Gap
MOQ: 1
Price: To be quoted
Standard Packaging: safety carton pack or plywood box
Payment Method: T/T
Detail Information
Place of Origin
China
Brand Name
Kingpo
Certification
ISO 17025
Model Number
KP-FT3541
Standards:
IEC 60335-2-40:2022 And GB/T 4706.32-2024
Electrode Spark Gap:
0.5-10mm Adjustable
Transformer Voltage Range:
0-20KV, Resolution 1V
Discharge Time:
0.3s ± 0.05s
Minimum Order Quantity:
1
Price:
To be quoted
Packaging Details:
safety carton pack or plywood box
Payment Terms:
T/T
Highlight

IEC 60335-2-40:2022 Compliant Flame Test Equipment

,

GB/T 4706.32-2024 Compliant A2L Refrigerant Test Chamber

,

Adjustable Electrode Spark Gap Flame-Retardant Enclosure Test Machine

Product Description
A2L Refrigerant Flame-Retardant Enclosure Verification Test Machine
Product Overview
The flame-retardant enclosure verification test chamber for A2L refrigerant is designed to test and verify the flame-retardant effect of enclosures during A2L refrigerant leakage scenarios. This equipment complies with IEC 60335-2-40:2022 and GB/T 4706.32-2024 standards, simulating refrigerant leakage to evaluate enclosure flame-retardant performance.
Equipment Functions and Standards
Designed according to international standards IEC 60335-2-40:2022 and GB/T 4706.32-2024, this testing machine is suitable for household appliances including electric heat pumps, air conditioners, and dehumidifiers.
  • Simulates refrigerant leakage scenarios to test flame-retardant enclosure effectiveness
  • Verifies whether the enclosure can effectively prevent flame spread after leakage
Equipment Composition
  • High-voltage spark generator (1 set)
  • Explosion-proof simulated environment chamber (1 set)
  • Control system (1 set)
Technical Parameters
Component Specification
High-voltage spark generator Included in system
Electrode Spark Gap 0.5-10mm adjustable
Transformer Voltage Range 0-20KV, resolution 1V
Discharge Time 0.3s ± 0.05s
Discharge Quantity 30mA; Resolution: 0.01mA
Dry Bulb Humidity 32℃ (adjustable)
Dew Point Temperature 27℃ (adjustable)
Voltage Input 220VAC