Product information:
The test equipment is designed and manufactured according to IEC60598-1 clause 4.4.4 standard test item requirements, test content: axial pressure is applied to the G5 lamp holder of 15N, 30N axial pressure exerted on the G13 lamp holders, pressure holding time I minutes, then quit, deformation detection lamp holder shall not exceed the amount of light foot length of 1 / 4.
It relates to an axial force testing device for a fluorescent lamp holder. The axial force testing device is characterized by comprising a base, wherein a test seat for positioning the lamp holder is arranged in the middle of the base, one side of the test seat is provided with a range finder, the other side of the test seat is provided with a linear guide rail, a thrust seat is installed on a sliding block of the linear guide rail, a pressure sensor and a test pressure head are installed on the thrust seat, and a stepping motor is connected with the thrust seat through a screw rod and a screw rod nut.
Technical parameters:
| Power | 220V 50Hz | 
| The axial force | 15N (bar weight), 30N (superimposed by a 15N vias weight onto the bar) | 
| Fixtures | V-type fixture, front and back adjustable | 
| Holding specimen height range | 0-250mm | 
 
          | MOQ: | 1 | 
| Price: | To be quoted | 
| Standard Packaging: | safety carton pack or plywood box | 
| Delivery Period: | 7 working days | 
| Payment Method: | T/T | 
| Supply Capacity: | 50 pcs per month | 
Product information:
The test equipment is designed and manufactured according to IEC60598-1 clause 4.4.4 standard test item requirements, test content: axial pressure is applied to the G5 lamp holder of 15N, 30N axial pressure exerted on the G13 lamp holders, pressure holding time I minutes, then quit, deformation detection lamp holder shall not exceed the amount of light foot length of 1 / 4.
It relates to an axial force testing device for a fluorescent lamp holder. The axial force testing device is characterized by comprising a base, wherein a test seat for positioning the lamp holder is arranged in the middle of the base, one side of the test seat is provided with a range finder, the other side of the test seat is provided with a linear guide rail, a thrust seat is installed on a sliding block of the linear guide rail, a pressure sensor and a test pressure head are installed on the thrust seat, and a stepping motor is connected with the thrust seat through a screw rod and a screw rod nut.
Technical parameters:
| Power | 220V 50Hz | 
| The axial force | 15N (bar weight), 30N (superimposed by a 15N vias weight onto the bar) | 
| Fixtures | V-type fixture, front and back adjustable | 
| Holding specimen height range | 0-250mm |