ISO16750-4 Clause 4.2 Splash Water Test Chamber Simulating Thermal Shock Testing On Vehicle Caused By Ice Water

Certification
China KingPo Technology Development Limited certification
China KingPo Technology Development Limited certification
Customer Reviews
Dear Supplier KINGPO TECHNOLOGY DEVELOPEMENT, In the ambit of ISO 9001:2015 certification, we intend to communicate the requirements as well as its percentage used on final evaluation used by ISQ to control and monitor its external supplier’s performance as per bellow: According with the above requirements to be maintained in future evaluations

—— ISQ Procurement Management

Good day and thank you for you According to the sample of the instrument you provided, we are very satisfied with our test. We want to change the order from 2 to 10. The following is the order details of our Asia Pacific branch. Would you please send me the quotation of the corresponding office? So we can generate an order to confirm it. Thank you.

—— Angel

I'm Online Chat Now

ISO16750-4 Clause 4.2 Splash Water Test Chamber Simulating Thermal Shock Testing On Vehicle Caused By Ice Water

ISO16750-4 Clause 4.2 Splash Water Test Chamber Simulating Thermal Shock Testing On Vehicle Caused By Ice Water
ISO16750-4 Clause 4.2 Splash Water Test Chamber Simulating Thermal Shock Testing On Vehicle Caused By Ice Water ISO16750-4 Clause 4.2 Splash Water Test Chamber Simulating Thermal Shock Testing On Vehicle Caused By Ice Water

Large Image :  ISO16750-4 Clause 4.2 Splash Water Test Chamber Simulating Thermal Shock Testing On Vehicle Caused By Ice Water

Product Details:
Place of Origin: China
Brand Name: KingPo
Certification: Calibration certificate
Model Number: KP-1023
Payment & Shipping Terms:
Minimum Order Quantity: 1
Price: To be Quoted
Delivery Time: 35
Payment Terms: T/T
Supply Ability: 25 per month
Detailed Product Description
Standard: ISO16750-4 Clause 4.2 Cycles: 100
The Holding Time Of The Specified Temperature Tmax Th: 1h Or Until The DUT Temperature Is Stable Conversion Duration: <20s (manual Conversion Between DUT Storage Temperature And Splash Temperature)
Test Liquid: Deionized Water + 3% Pure Arizona Dust Or 5% Sodium Water Temperature: 0~+4°C
High Light:

ozone test chamber

,

temperature and humidity chamber

 

ISO16750-4 Clause 4.2 Water Splash Test Chamber Simulating Thermal Shock Testing On Vehicle Caused By Ice Water

 

Purpose 

The product used in the shallow water area of the vehicle simulates thermal shock testing caused by ice water. The purpose is to simulate the splashing of ice water into a heating system or component while driving on a wet road in winter. A failure mode is a temperature expansion coefficient that causes mechanical cracking or seal failure. Another additional failure mode, not covered in 5.3.3, is the reduction in tightness and water intrusion into systems or components.

There are two ways to perform the test (see sections 4.2 and 4.3)

 

Test

Heat the DUT (device under test) to a certain temperature max) and the specified time (hours) in an oven. Spray the ice water to the DUT for 3 seconds.

 

ISO16750-4 Clause 4.2 Splash Water Test Chamber Simulating Thermal Shock Testing On Vehicle Caused By Ice Water 0

               ISO16750-4 Clause 4.2 Splash Water Test Chamber Simulating Thermal Shock Testing On Vehicle Caused By Ice Water 1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

If the DUT is only splashed in one direction on the vehicle, it will only spray in the direction of the installation position. If the equipment is splashed in multiple directions on the vehicle, these directions should be stated, and each direction is tested with a new DUT. The width of the splash is always greater than the width of the DUT. If the size of the DUT that accepts splashing water is much larger than the single sprinkler head, multiple nozzles should be arranged to splash water into the DUT in rows.

 

 

Cycles 100
The holding time of the specified temperature Tmax th 1h or until the DUT temperature is stable
Conversion duration <20s (manual conversion between DUT storage temperature and splash temperature)
Test liquid Deionized water + 3% pure Arizona dust or 5% sodium
Water temperature 0~+4°C
Water flow 3L-4L/3s (jetting process)
Spout to DUT distance 325 ± 25mm (provided water should exceed the width of the DUT)
Working mode (ISO16750-1) See Figure 5
Direction of the DUT Same as loading direction