Straight Twist Test Apparatus Cable Testing Equipment Linear Torsion Machine
Product Details:
Place of Origin: | China |
Brand Name: | KingPo |
Certification: | calibration certificate |
Model Number: | KP-NZ-2D |
Payment & Shipping Terms:
Minimum Order Quantity: | 1 |
---|---|
Price: | To be Quoted |
Packaging Details: | safety tool box or plywood pack. |
Delivery Time: | 25 working days |
Payment Terms: | T/T |
Supply Ability: | 100 sets per month |
Detail Information |
|||
Standard: | JIS C3005 FIG.5-(a) | Power Supply: | AC220V 50HZ 500W Three-station Independent |
---|---|---|---|
Torsion Speed: | 5-60 Laps/min Optional | Torsion Angle: | 0-±180° (360°) Can Be Set |
Adjustable Torsion Diameter: | R Size | Drive: | Servo Motor |
Highlight: | High Frequency Spark Tester,Bend Test Machine |
Product Description
JIS C3005 FIG.5-(a) Straight Twist Test Apparatus / Three Stations Linear Torsion Machine
Twist test
Twisting test is carried out by two types define their own way of our criteria.
(A)Straight twist test
Mount a sample of about 1m taked from the finished product,attach it to the straight twist test apparatus of FIG.5-(a).Given to the number of time twisting around at a rate of per minute about 60 times so that the rotor to the appropriate angle(θ).At this time,not occur a short circuit between the lines,no crack about surface of the insulation and the exterior,and other abnormalities that there is no.
Standard requirement:
Number of trials: adjustable
Torsion speed: 60 times / min
Torsion angle: 360°
Weight F: 5N/mm2
Replacement fixture
Sample length: 1000mm
Technical Parameters:
1. Power supply: AC220V 50HZ 500W three-station independent
2. Torsion speed: 5-60 laps/min optional.
3. Torsion angle: 0-±180° (360°) can be set
4. Adjustable torsion diameter (R size)
5. Counting times: 9999999 times, can be set, accuracy ± 1 time
6. Servo motor drive
7. Touch screen settings and operations
8. Test mode: continuity test, mechanical test
9. Multi-core test: single off alarm stop, full off alarm stop, count to stop, etc.
Alarm mode: qualified prompt alarm, unqualified alarm and retain the number of tests.