logo
Send Message
products
PRODUCTS DETAILS
Home > Products >
IEC 60601-1 Hand Transmitted Vibration Meter with 100mV/g Sensor Sensitivity and 0.5Hz ~ 400Hz Frequency Range

IEC 60601-1 Hand Transmitted Vibration Meter with 100mV/g Sensor Sensitivity and 0.5Hz ~ 400Hz Frequency Range

MOQ: 1
Price: To be quoted
Standard Packaging: safety carton pack or plywood box
Delivery Period: 7 working days
Payment Method: T/T
Supply Capacity: 50 pcs per month
Detail Information
Place of Origin
china
Brand Name
kingpo
Certification
iso9001 ce
Model Number
6259
According To:
IEC 60601-1 Clause9.6.3
Frequency Range:
0.5Hz ~ 400Hz.
Measuring Range:
60 DB~180 DB.
Sensor Sensitivity:
100mV/g
Highlight:

IEC 60601-1- Vibration Meter

,

Hand transmitted Vibration Meter

,

100mV/g Sensor Sensitivity vibration Meter

Product Description
IEC 60601-1 Hand Transmitted Vibration Meter With 100mV/g Sensor Sensitivity
Product Overview
Professional IEC 60601-1 compliant hand-transmitted vibration meter designed for medical electrical equipment testing and measurement applications.
Technical Specifications
  • Compliance: IEC 60601-1 clause 9.6.3
  • Channels: 3
  • Frequency Range: 0.5Hz ~ 400Hz
  • Measuring Range: 60 dB ~ 180 dB
  • Sensor Weight: 300g
  • Sensor Sensitivity: 100mV/g
  • Frequency Options: Line, Wd, Wk, Wm, Wh, VLz, Wb, Wc, We, Wj
  • Time Settings: F (0.125s), S (1s), stable (8s)
  • Average Score Time: 1s to 24h arbitrary setting
  • Display Refresh Rate: Instantaneous value 0.5s refresh once
  • Display: 3.5-inch color screen, 320*480 dot matrix, touch screen
Standard Configuration
1 host, 1 whole body vibration acceleration sensor, 1 carrying box, 1 manual
IEC 60601-1 Hand Transmitted Vibration Meter with 100mV/g Sensor Sensitivity and 0.5Hz ~ 400Hz Frequency Range 0
Testing and Measuring Equipment Requirements
IEC 60601-1:2005 + Am.1:2012 Compliance
Medical electrical equipment - Part 1: General requirements for basic safety and essential performance
Clause Measurement/Testing Testing/Measuring Equipment Needed Subcontracting
4.11 Power input Suitable devices for voltage, current/power and frequency supply: 1 phase and 3 phase variacs R
5.3 Ambient temperature, humidity, atmospheric pressure Suitable devices for recording ambient temperature, humidity, atmospheric pressure R
5.7 Humidity preconditioning treatment Environmental conditions: Climate chamber controlling temperature and humidity R
5.9.2 Accessible parts Force gauge (30 N), standard test finger (figure 6), straight unjointed test finger, test hook (figure 7) R
7.1.2 Legibility of markings Illuminance meter R
7.1.3 Durability of markings Distilled water, ethanol (96% pure), isopropyl alcohol, timer/stop watch R
8.4.2 Accessible parts including applied parts Oscilloscope, oscilloscope leads, suitable instruments for measuring voltage, current, capacitance, test pin (Figure 8), metal test rod (D = 4 mm, L = 100 mm), force gauge (10 N) R
8.4.3, 8.4.4 Limitations voltage and energy Suitable oscilloscope recorder/set-up & RCL meter R
8.5.5.1 Defibrillation protection 5 kV test circuit & oscilloscope interface circuit according to Figures 9 & 10, oscilloscope S
8.5.5.2 Energy reduction test The test circuit according to Figure 11, oscilloscope, oscilloscope leads S
8.6.4 Impedance and current-carrying capability Current source (25 A minimum, 50 or 60 Hz, 6 V maximum) R
8.7 Leakage currents and patient auxiliary currents Measuring device according to Figure 12, mains isolation transformers, variacs, voltmeter, millivoltmeter, aluminium foil, diverse circuits (fig. 13-20) R
8.8.3 Dielectric strength High voltage tester, isolating transformer for HV-tests (fig. 28), stop watch/timer R
8.8.4.1 a) Ball pressure test Test equipment according to IEC 60695-10-2 R
8.8.4.2 Resistance to environmental stress Apparatus for ageing rubber in oxygen S
8.9 Creepage distances and air clearances Oscilloscope, oscilloscope leads, callipers, micrometer, spacing gauges, force gauge (2 N & 30 N), standard test finger (figure 6) R
8.9.1.7 Material groups classification Test equipment according to IEC 60112 S
8.9.3.4 Thermal cycling Heating cabinet R
8.11.3.5 Cord anchorage Force gauge (at least 100 N), torque gauge (at least 0.35 Nm) R
8.11.3.6 Cord guards Weights, angle gauge, radius gauge R
9.4 Instability hazards 5° & 10° inclined planes or inclinometer or trigonometric calculation, force gauge (at least 220 N), 20 cm by 20 cm test surface, weights, test threshold (10 mm high and 80 mm wide), 7 cm strap, stop watch/timer R
9.5.2 Cathode ray tubes The relevant tests of IEC 60065, Clause 18. S
9.6.2.1 Audible acoustic energy A-weighted sound pressure level according to ISO 3746, ISO 9614-1 or IEC 61672-1 S
9.6.3 Hand-transmitted vibration Measurements are made in accordance with ISO 5349-1. S
9.7.5 Pressure vessels Hydraulic pressure test apparatus S
9.8 Hazards associated with support systems Weights or load cell, 0.1 m2 test surface, stop watch/timer, human body test mass (Figure 33) R
10.1 X-radiation Radiation meter S
10.3 Microwave radiation Radiation meter S
10.4 Lasers Test equipment according to IEC 60825-1 S
11.1 Excessive temperatures Temperature indicator/recorder suitable for this function and thermocouples, 4 wire resistance unit, test corner, variac R
11.2 Fire prevention Spark ignition test apparatus (Figure 34), oxygen gas analyzer S
11.3 Constructional requirements for fire enclosures FV tests specified in IEC 60695-11-10 S
11.6.2 Overflow 15° inclined plane or inclinometer or trigonometric calculation, stop watch/timer, high voltage tester R
11.6.3 Spillage Flask or graduated cylinder, stop watch/timer R
11.6.5 Ingress of water or particulate matter Classification tests of IEC 60529 W
11.6.6 Cleaning and disinfection Dielectric strength and leakage current tests as appropriate R
11.6.7 Sterilization Sterilisation to client specification S
13 Hazardous situations and fault conditions Stop watch/timer, voltmeter, ammeter, temperature indicator/recorder suitable for this function and thermocouples, 4 wire resistance unit, cheesecloth R
15.3 Mechanical strength Force gauge (250 N minimum), circular plane surface 30 mm in diameter, 500 g steel ball, 50 mm thick hardwood board (hardwood > 600 kg/m3), 40 mm step, hardwood doorframe (40 mm2), circulating air oven R
15.4.2 Temperature and overload control devices Positive temperature coefficient devices (PTC's) with IEC 60730-1: 1999, clauses 15, 17, J.15 and J.17 S
15.4.3.4 Primary Lithium batteries Performance of the tests identified in IEC 60086-4 S
15.4.3.4 Secondary Lithium batteries Performance of the tests identified in IEC 62133 S
15.4.6 Actuating parts of controls Force gauge (at least 100 N), torque gauge (at least 6 Nm), stop watch/timer R
15.4.7 Cord-connected hand-held and foot-operated control devices Force gauge (minimum 1,350 N), 30 mm diameter test tool, stop watch/timer R
15.4.7.3 Entry of liquids Classification tests of IEC 60529 W
15.5.1.1 Transformers Winding tester for transformers, temperature indicator/recorder suitable for this function and thermocouples variac, loads R
15.5.2 Dielectric strength 5x voltage / 5x frequency dielectric strength test fixture, stop watch/timer R
16.6 Leakage currents As in sub-clause 8.7 R
A 10.4 Light emitting diodes (LEDs) As specified in IEC 62471 S
G Protection against hazards of ignition of flammable anaesthetic mixtures 4 mm & 12 mm diameter test rods, timer/stop watch, gasket test B-b of IEC 60068-2-2, force gauge (minimum 100 N), gas pressure meter (0 to 400 Pa range), voltmeter, ammeter, ohmmeter, meter for capacitance and inductance, oxygen mixture (volume percentage 12.2% ± 0.4%), test apparatus for flammable mixtures (Figure G.7) S
G.4.3 Prevention of electrostatic charges Antistatic material testing according to ISO 2882 S
L Insulated winding wires for use without interleaved insulation Sample preparation according to IEC 60851-5:1996 & dielectric according to 60601-1; flexibility and adherence test 8 of IEC 60851-3:1996; mandrels of diameters according to Table L.1; heat shock test 9 of IEC 60851-6:1996; 2 mm diameter shot of stainless steel, nickel or nickel plated iron S
products
PRODUCTS DETAILS
IEC 60601-1 Hand Transmitted Vibration Meter with 100mV/g Sensor Sensitivity and 0.5Hz ~ 400Hz Frequency Range
MOQ: 1
Price: To be quoted
Standard Packaging: safety carton pack or plywood box
Delivery Period: 7 working days
Payment Method: T/T
Supply Capacity: 50 pcs per month
Detail Information
Place of Origin
china
Brand Name
kingpo
Certification
iso9001 ce
Model Number
6259
According To:
IEC 60601-1 Clause9.6.3
Frequency Range:
0.5Hz ~ 400Hz.
Measuring Range:
60 DB~180 DB.
Sensor Sensitivity:
100mV/g
Minimum Order Quantity:
1
Price:
To be quoted
Packaging Details:
safety carton pack or plywood box
Delivery Time:
7 working days
Payment Terms:
T/T
Supply Ability:
50 pcs per month
Highlight

IEC 60601-1- Vibration Meter

,

Hand transmitted Vibration Meter

,

100mV/g Sensor Sensitivity vibration Meter

Product Description
IEC 60601-1 Hand Transmitted Vibration Meter With 100mV/g Sensor Sensitivity
Product Overview
Professional IEC 60601-1 compliant hand-transmitted vibration meter designed for medical electrical equipment testing and measurement applications.
Technical Specifications
  • Compliance: IEC 60601-1 clause 9.6.3
  • Channels: 3
  • Frequency Range: 0.5Hz ~ 400Hz
  • Measuring Range: 60 dB ~ 180 dB
  • Sensor Weight: 300g
  • Sensor Sensitivity: 100mV/g
  • Frequency Options: Line, Wd, Wk, Wm, Wh, VLz, Wb, Wc, We, Wj
  • Time Settings: F (0.125s), S (1s), stable (8s)
  • Average Score Time: 1s to 24h arbitrary setting
  • Display Refresh Rate: Instantaneous value 0.5s refresh once
  • Display: 3.5-inch color screen, 320*480 dot matrix, touch screen
Standard Configuration
1 host, 1 whole body vibration acceleration sensor, 1 carrying box, 1 manual
IEC 60601-1 Hand Transmitted Vibration Meter with 100mV/g Sensor Sensitivity and 0.5Hz ~ 400Hz Frequency Range 0
Testing and Measuring Equipment Requirements
IEC 60601-1:2005 + Am.1:2012 Compliance
Medical electrical equipment - Part 1: General requirements for basic safety and essential performance
Clause Measurement/Testing Testing/Measuring Equipment Needed Subcontracting
4.11 Power input Suitable devices for voltage, current/power and frequency supply: 1 phase and 3 phase variacs R
5.3 Ambient temperature, humidity, atmospheric pressure Suitable devices for recording ambient temperature, humidity, atmospheric pressure R
5.7 Humidity preconditioning treatment Environmental conditions: Climate chamber controlling temperature and humidity R
5.9.2 Accessible parts Force gauge (30 N), standard test finger (figure 6), straight unjointed test finger, test hook (figure 7) R
7.1.2 Legibility of markings Illuminance meter R
7.1.3 Durability of markings Distilled water, ethanol (96% pure), isopropyl alcohol, timer/stop watch R
8.4.2 Accessible parts including applied parts Oscilloscope, oscilloscope leads, suitable instruments for measuring voltage, current, capacitance, test pin (Figure 8), metal test rod (D = 4 mm, L = 100 mm), force gauge (10 N) R
8.4.3, 8.4.4 Limitations voltage and energy Suitable oscilloscope recorder/set-up & RCL meter R
8.5.5.1 Defibrillation protection 5 kV test circuit & oscilloscope interface circuit according to Figures 9 & 10, oscilloscope S
8.5.5.2 Energy reduction test The test circuit according to Figure 11, oscilloscope, oscilloscope leads S
8.6.4 Impedance and current-carrying capability Current source (25 A minimum, 50 or 60 Hz, 6 V maximum) R
8.7 Leakage currents and patient auxiliary currents Measuring device according to Figure 12, mains isolation transformers, variacs, voltmeter, millivoltmeter, aluminium foil, diverse circuits (fig. 13-20) R
8.8.3 Dielectric strength High voltage tester, isolating transformer for HV-tests (fig. 28), stop watch/timer R
8.8.4.1 a) Ball pressure test Test equipment according to IEC 60695-10-2 R
8.8.4.2 Resistance to environmental stress Apparatus for ageing rubber in oxygen S
8.9 Creepage distances and air clearances Oscilloscope, oscilloscope leads, callipers, micrometer, spacing gauges, force gauge (2 N & 30 N), standard test finger (figure 6) R
8.9.1.7 Material groups classification Test equipment according to IEC 60112 S
8.9.3.4 Thermal cycling Heating cabinet R
8.11.3.5 Cord anchorage Force gauge (at least 100 N), torque gauge (at least 0.35 Nm) R
8.11.3.6 Cord guards Weights, angle gauge, radius gauge R
9.4 Instability hazards 5° & 10° inclined planes or inclinometer or trigonometric calculation, force gauge (at least 220 N), 20 cm by 20 cm test surface, weights, test threshold (10 mm high and 80 mm wide), 7 cm strap, stop watch/timer R
9.5.2 Cathode ray tubes The relevant tests of IEC 60065, Clause 18. S
9.6.2.1 Audible acoustic energy A-weighted sound pressure level according to ISO 3746, ISO 9614-1 or IEC 61672-1 S
9.6.3 Hand-transmitted vibration Measurements are made in accordance with ISO 5349-1. S
9.7.5 Pressure vessels Hydraulic pressure test apparatus S
9.8 Hazards associated with support systems Weights or load cell, 0.1 m2 test surface, stop watch/timer, human body test mass (Figure 33) R
10.1 X-radiation Radiation meter S
10.3 Microwave radiation Radiation meter S
10.4 Lasers Test equipment according to IEC 60825-1 S
11.1 Excessive temperatures Temperature indicator/recorder suitable for this function and thermocouples, 4 wire resistance unit, test corner, variac R
11.2 Fire prevention Spark ignition test apparatus (Figure 34), oxygen gas analyzer S
11.3 Constructional requirements for fire enclosures FV tests specified in IEC 60695-11-10 S
11.6.2 Overflow 15° inclined plane or inclinometer or trigonometric calculation, stop watch/timer, high voltage tester R
11.6.3 Spillage Flask or graduated cylinder, stop watch/timer R
11.6.5 Ingress of water or particulate matter Classification tests of IEC 60529 W
11.6.6 Cleaning and disinfection Dielectric strength and leakage current tests as appropriate R
11.6.7 Sterilization Sterilisation to client specification S
13 Hazardous situations and fault conditions Stop watch/timer, voltmeter, ammeter, temperature indicator/recorder suitable for this function and thermocouples, 4 wire resistance unit, cheesecloth R
15.3 Mechanical strength Force gauge (250 N minimum), circular plane surface 30 mm in diameter, 500 g steel ball, 50 mm thick hardwood board (hardwood > 600 kg/m3), 40 mm step, hardwood doorframe (40 mm2), circulating air oven R
15.4.2 Temperature and overload control devices Positive temperature coefficient devices (PTC's) with IEC 60730-1: 1999, clauses 15, 17, J.15 and J.17 S
15.4.3.4 Primary Lithium batteries Performance of the tests identified in IEC 60086-4 S
15.4.3.4 Secondary Lithium batteries Performance of the tests identified in IEC 62133 S
15.4.6 Actuating parts of controls Force gauge (at least 100 N), torque gauge (at least 6 Nm), stop watch/timer R
15.4.7 Cord-connected hand-held and foot-operated control devices Force gauge (minimum 1,350 N), 30 mm diameter test tool, stop watch/timer R
15.4.7.3 Entry of liquids Classification tests of IEC 60529 W
15.5.1.1 Transformers Winding tester for transformers, temperature indicator/recorder suitable for this function and thermocouples variac, loads R
15.5.2 Dielectric strength 5x voltage / 5x frequency dielectric strength test fixture, stop watch/timer R
16.6 Leakage currents As in sub-clause 8.7 R
A 10.4 Light emitting diodes (LEDs) As specified in IEC 62471 S
G Protection against hazards of ignition of flammable anaesthetic mixtures 4 mm & 12 mm diameter test rods, timer/stop watch, gasket test B-b of IEC 60068-2-2, force gauge (minimum 100 N), gas pressure meter (0 to 400 Pa range), voltmeter, ammeter, ohmmeter, meter for capacitance and inductance, oxygen mixture (volume percentage 12.2% ± 0.4%), test apparatus for flammable mixtures (Figure G.7) S
G.4.3 Prevention of electrostatic charges Antistatic material testing according to ISO 2882 S
L Insulated winding wires for use without interleaved insulation Sample preparation according to IEC 60851-5:1996 & dielectric according to 60601-1; flexibility and adherence test 8 of IEC 60851-3:1996; mandrels of diameters according to Table L.1; heat shock test 9 of IEC 60851-6:1996; 2 mm diameter shot of stainless steel, nickel or nickel plated iron S