MOQ: | 1 |
Price: | To be quoted |
Payment Method: | T/T |
The Energy Storage Battery Performance Test Equipment is designed for comprehensive evaluation of various energy storage systems, including mobile, home, industrial, and outdoor applications, as well as power lithium batteries and mobile base station backup power supplies.
Utilizing advanced digital signal processing technology and high-precision sensors, this equipment provides real-time monitoring of battery operational status and performance, assessing critical parameters including voltage, current, capacity, dynamic internal resistance, and temperature.
The system supports extensive testing capabilities, including battery life aging, pack capacity, charging/discharge characteristics, charge retention, efficiency, and tolerance to overcharge/overdischarge conditions. Customizable comparison conditions enable precise control of charging/discharging processes for balanced operation.
Parameter | Specification |
---|---|
Phase number | Three phases |
Voltage and frequency | AC380V±15% 50/60±5Hz |
Input power factor | ≥99% (full power) |
THDi | ≤5% (full power) |
Input impedance | ≥1MΩ |
Overall machine efficiency | ≥92% (full power) |
Parameter | Specification |
---|---|
Number of channels | 2-16 |
Charge/discharge voltage | Charge 0V-120V; Discharge 6V |
Current range | 30A/60A/100A/120A |
Voltage/Current accuracy | ±0.05%FS |
Current response time | ≤10ms (10%FS-90%FS) |
Charge/discharge transition | ≤20ms (-90%FS-90%FS) |
Parameter | Specification |
---|---|
Communication interface | Ethernet, CAN, 485, etc. |
Charging mode | Constant current, constant voltage, constant power, current pulse, power pulse, DC internal resistance, etc. |
Discharge mode | Constant current, constant voltage, constant power, current pulse, power pulse, DC internal resistance, etc. |
Noise | ≤75dB |
Cooling method | Forced air cooling |
Protection functions | Short-circuit, overload, overvoltage, undervoltage, island protection, temperature alarm, power failure data protection, and various other protective functions |
MOQ: | 1 |
Price: | To be quoted |
Payment Method: | T/T |
The Energy Storage Battery Performance Test Equipment is designed for comprehensive evaluation of various energy storage systems, including mobile, home, industrial, and outdoor applications, as well as power lithium batteries and mobile base station backup power supplies.
Utilizing advanced digital signal processing technology and high-precision sensors, this equipment provides real-time monitoring of battery operational status and performance, assessing critical parameters including voltage, current, capacity, dynamic internal resistance, and temperature.
The system supports extensive testing capabilities, including battery life aging, pack capacity, charging/discharge characteristics, charge retention, efficiency, and tolerance to overcharge/overdischarge conditions. Customizable comparison conditions enable precise control of charging/discharging processes for balanced operation.
Parameter | Specification |
---|---|
Phase number | Three phases |
Voltage and frequency | AC380V±15% 50/60±5Hz |
Input power factor | ≥99% (full power) |
THDi | ≤5% (full power) |
Input impedance | ≥1MΩ |
Overall machine efficiency | ≥92% (full power) |
Parameter | Specification |
---|---|
Number of channels | 2-16 |
Charge/discharge voltage | Charge 0V-120V; Discharge 6V |
Current range | 30A/60A/100A/120A |
Voltage/Current accuracy | ±0.05%FS |
Current response time | ≤10ms (10%FS-90%FS) |
Charge/discharge transition | ≤20ms (-90%FS-90%FS) |
Parameter | Specification |
---|---|
Communication interface | Ethernet, CAN, 485, etc. |
Charging mode | Constant current, constant voltage, constant power, current pulse, power pulse, DC internal resistance, etc. |
Discharge mode | Constant current, constant voltage, constant power, current pulse, power pulse, DC internal resistance, etc. |
Noise | ≤75dB |
Cooling method | Forced air cooling |
Protection functions | Short-circuit, overload, overvoltage, undervoltage, island protection, temperature alarm, power failure data protection, and various other protective functions |