Technical Specifications
Voltage and Current Parameters
Voltage Series Basic Model Voltage/Current Accuracy Minimum Charge/Discharge Current (mA) Minimum Discharge Voltage (V) Current Response Time (10%-90%FS) Charge/Discharge Conversion Time
30V Series HD-30V30A-40CH 0.05%FS 30mA 6V 10ms 20ms
HD-30V60A-40CH 0.05%FS 30mA 6V 10ms 20ms
60V Series HD-60V30A-40CH 0.05%FS 30mA 6V 10ms 20ms
HD-60V60A-40CH 0.05%FS 30mA 6V 10ms 20ms
100V Series HD-100V30A-40CH 0.05%FS 30mA 6V 10ms 20ms
Power and Physical Specifications
Voltage Series Basic Model Maximum Charging Efficiency Maximum Regenerative Efficiency Input Voltage Power Weight (KG) Cabinet Dimensions
30V Series HD-30V30A-40CH 92% 90% AC380V 50/60±5Hz Three-phase five-wire system 36KW ≤350KG W:1530mm H:1980mm D:880mm
HD-30V60A-40CH 92% 90% 72KW
60V Series HD-60V30A-40CH 92% 90% 72KW ≤350KG
HD-60V60A-40CH 92% 90% 144KW
100V Series HD-100V30A-40CH 92% 90% 120KW ≤350KG
products
PRODUCTS DETAILS
40CH Battery Test System 30V-100V Series with 0.05% Accuracy
MOQ: 1
Price: To be quoted
Payment Method: T/T
Detail Information
Place of Origin
China
Brand Name
Kingpo
Minimum Order Quantity:
1
Price:
To be quoted
Payment Terms:
T/T
Highlight

40CH battery test system

,

30V-100V battery tester

,

high-accuracy battery testing equipment

Product Description
40CH Integrated Cabinet Battery Charge and Discharge Test System
Technical Specifications
Voltage and Current Parameters
Voltage Series Basic Model Voltage/Current Accuracy Minimum Charge/Discharge Current (mA) Minimum Discharge Voltage (V) Current Response Time (10%-90%FS) Charge/Discharge Conversion Time
30V Series HD-30V30A-40CH 0.05%FS 30mA 6V 10ms 20ms
HD-30V60A-40CH 0.05%FS 30mA 6V 10ms 20ms
60V Series HD-60V30A-40CH 0.05%FS 30mA 6V 10ms 20ms
HD-60V60A-40CH 0.05%FS 30mA 6V 10ms 20ms
100V Series HD-100V30A-40CH 0.05%FS 30mA 6V 10ms 20ms
Power and Physical Specifications
Voltage Series Basic Model Maximum Charging Efficiency Maximum Regenerative Efficiency Input Voltage Power Weight (KG) Cabinet Dimensions
30V Series HD-30V30A-40CH 92% 90% AC380V 50/60±5Hz Three-phase five-wire system 36KW ≤350KG W:1530mm H:1980mm D:880mm
HD-30V60A-40CH 92% 90% 72KW
60V Series HD-60V30A-40CH 92% 90% 72KW ≤350KG
HD-60V60A-40CH 92% 90% 144KW
100V Series HD-100V30A-40CH 92% 90% 120KW ≤350KG